Able Planet 620DuN Fan User Manual


 
Watson-Marlow 620DuN and 620Du User Manual 38
18.5 Baud
The pump can be set to communicate with control devices at a choice of baud rates.
In the first screen of the Setup menu select Baud using the UP and DOWN
keys. Press ENTER to confirm your choice.
The pump displays a screen allowing you to change the pump’s baud rate. Use
the UP and DOWN keys to select 1200, 2400, 4800 or 9600 (or, 620DuN
only, 19k2) and press ENTER to confirm your decision.
The pump displays the first screen of the Setup menu.
18.6 Stop bits
The pump can be set to communicate with control devices at a choice of stop bits
settings.
In the second screen of the Setup menu select Stop bits using the UP and
DOWN keys. Press ENTER to confirm your choice.
The pump displays a screen allowing you to change the pump’s stop bits set-
ting. Use the UP and DOWN keys to select 2, 1, or 0 and press ENTER to
confirm your decision.
The pump displays the second screen of the Setup menu.
18.7 Xon/Xoff
The pump can be set to communicate with control devices using Xon/Xoff flow con-
trol.
In the second screen of the Setup menu select Xon/Xoff using the UP and
DOWN keys. Press ENTER to confirm your choice.
The pump displays a screen allowing you to set flow control on or off. Use the
UP and DOWN keys to choose and press ENTER to confirm your decision.
The pump displays the second screen of the Setup menu.