A SERVICE OF

logo

15 - 50
15. SERVO AMPLIFIERS WITH A LARGE CAPACITY
(
30k TO 55kW
)
(b) Display definition
The LED segment corresponding to the pin is lit to indicate ON, and is extinguished to indicate OFF.
The 7-segment LED segments and CN1 connector pins correspond as shown below.
Lit: ON
Extinguished: OFF
Input signals
Output signals
CN1-7: Forced stop (EM1)
CN1-8:
Warning (WNG)
CN1-2:
Trouble (ALM)
(3) Output signal forced output
You can force the output signal to be switched on/off, independently of the converter status.
This function is used for wiring check of output signal. Indicates the display screen shown after power-on.
When turning CN1-8 on and off
External I/O signal display screen
Press SET for longer than 2 seconds.
CN1-8
CN1-8 CN1-2
Press MODE once.
Press UP once.
The signal under the lit LED is switched on/off.
Indicates ON/OFF of the trouble (ALM) signal. (Lit: ON, extinguished: OFF)
Press MODE once.
The lit LED moves to the upper LED of CN1-8.
Press UP once.
CN1-8 switches on. (WNG-DOCOM are connected.)
Press DOWN once.
CN1-8 switches off.
Press SET for longer than 2 seconds.