3-72 C122-E003-02EN
MMB
CHAPTER 3 Web-UI Operations
Figure 3.26 [PCI_Box#x] window (2/2)
Table 3.47 Displayed items in the [PCI_Box#x] window
Item Description
PCI_Box Information
Status PCI_Box status:
• OK: Operating normally
• Not present: Not installed
• Warning: Warning status (A problem will possibly occur.)
• Degraded: Component failure (The faulty component can be
isolated to continue operation.)
• Failed: Failure
Power Status Power status:
• On: Powered on
• Standby: Standby mode
Power Supply
Redundancy
Redundancy status of the IO_PSU:
• Fully redundant:
Redundancy in the PSU configuration is maintained.
• [Non-Redundant:
Sufficient Resources]: The IO_PSU redundancy has been lost,
but the fans are sufficient for system operation.
• [Non-Redundant: Insufficient Resources]:
The IO_PSU redundancy has been lost and the fans are
insufficient for system operation.