The DIP switch settings for the Standard and Alternate sets are:
DIP
Switch
1-6
1-7
1-8
Standard Alternate
ON
Set any one of
ON
these three
ON
switches to OFF.
Running the self test in the IBM Proprinter mode
If you want to run a self test to see what the IBM Proprinter charac-
ter sets look like, you only have to reset DIP switch 1-4 from ON to
OFF.
To run the self test, make sure the power is OFF, then hold down the
DRAFT button while turning the power switch ON-the self test
takes over and the FX-286 starts printing out the Standard IBM Pro-
printer character set, as shown in Figure J-1.
Figure J-1. IBM Proprinter mode self test
If you want to see the Alternate set, turn the power OFF. Then reset
either switch
1-6, 1-7,
or
1-8
from ON to OFF, and run the self test
again.
Remember, you must also reset DIP switches
2-1
and
2-3
as previ-
ously mentioned if you want to select the IBM Proprinter mode for
uses other than the self test.