A SERVICE OF

logo

show spantree lpwindow Configuring Spanning Tree Loop Protect Features
Enterasys Matrix DFE-Gold Series Configuration Guide 6-73
counterisnotresetuntiltheLoopProtecteventthresholdisreached.Ifthethresholdisreached,
thatconstitutesaloopprotectionevent.
Example
ThisexampleshowshowtosettheLoopProtecteventwindowto120seconds:
Matrix(rw)->set spantree lpwindow 120
show spantree lpwindow
UsethiscommandtodisplaythecurrentLoopProtecteventwindowvalue.
Syntax
show spantree lpwindow
Parameters
None.
Defaults
None.
Mode
Switchcommand,ReadOnly.
Example
ThisexampleshowshowtodisplaythecurrentLoopProtectwindowvalue:
Matrix(rw)->show spantree lpwindow
LoopProtect event window is set to 120 seconds
clear spantree lpwindow
UsethiscommandtoresettheLoopProtecteventwindowtothedefaultvalueof180seconds.
Syntax
clear spantree lpwindow
Parameters
None.
Defaults
None.
Mode
Switchcommand,ReadWrite.