A-10
Cisco ONS 15310-MA SDH Reference Manual, Release 9.1 and Release 9.2
78-19417-01
Appendix A Specifications
SFP Specifications
The 15310-CL-CTX card does not have a faceplate because it is located inside the chassis; therefore, the
two SFP slots are located on the ONS 15310-CL faceplate, just to the left of the LAN port. The two SFP
slots on the 15310E-CTX-K9 are located on 15310E-CTX-K9 faceplate.
Table A-2 SFP Specifications
SFP Product ID Interface
Transmitter Output
Power Min/Max (dBm)
Receiver Input Power
Min/Max (dBm)
ONS-SI-155-L1 OC-3 –5.0 to 0 –34 to –10
ONS-SI-155-L2 OC-3 –5.0 to 0 –34 to –10
ONS-SI-155-I1 OC-3 –15 to –8.0 –28 to –8
ONS-SI-622-L1 OC-12 –3.0 to 2.0 –28 to –8
ONS-SI-622-L2 OC-12 –3.0 to 2.0 –28 to –8
ONS-SI-622-I1 OC-12/OC-3 –15 to –8.0 –28 to –8
ONS-SI-155-SR-MM= OC-3/STM-1 –20 to –14 –30 to –14
ONS-SE-155-1470= through
ONS-SE-155-1610=
OC-3 0 to +5 –34 to –3 (at BER
10
-10
)
ONS-SE-622-1470= through
ONS-SE-622-1610=
OC-12 0 to +5 –28 to –3 (at BER
10
-10
)
ONS-SI-2G-I1= OC-48 –5.0 to 0 –18 to –0
ONS-SI-2G-L1= OC-48 –3 to +2 –27 to –9
ONS-SI-2G-L2= OC-48 –3 to +2 –28 to –9
ONS-SI-2G-S1= OC-48 –10 to -3 –18 to –3
ONS-SC-2G-28.7=
1
through
ONS-SC-2G-60.6=
1. ONS-SC-2G-28.7, ONS-SC-2G-33.4, ONS-SC-2G-41.3, ONS-SC-2G-49.3, and ONS-SC-2G-57.3 are supported from
Release 8.5 and later.
OC-48 0 to +4 –28 to –9
ONS-SE-Z1= OC-3/STM1
OC-12/STM-4
OC-48/STM-16
Fibre Channel
(1 and 2 Gbps)
GE
–5 to 0 –18 (OC-48/STM-16)
–22 (GE)
–23 (OC-12/STM-4)
–23 (OC-3/STM-1)
ONS-SI-155-SR-MM= OC-3, STM-1 –19 to –14 –14 to –5
ONS-SC-155-EL STM1 — —
Table A-3 CE-MR-6 SFP Specifications
SFP Product ID Interface
Transmitter Output
Power Min/Max (dBm)
Receiver Input Power
Min/Max (dBm)
ONS-SI-GE-SX GE –9.5 to 0 –17 to 0
ONS-SI-GE-LX GE –9.5 to –3 –19 to –3
ONS-SI-GE-ZX GE 0 to 5 –23 to –3