Chapter 10 Alarm Monitoring and Management
Alarm Suppression
10.4.5 Row Display Options
In the network view, the Alarm Profiles window displays two check boxes at the bottom of the window:
Hide reference values—Highlights alarms with non-default severities by clearing alarm cells with
default severities. This check-box is normally greyed out. It becomes active only when more than
one profile is listed in the Alarm Profile Editor window. (The check box text changes to “Hide
Values matching profile Default” in this case.
Hide identical rows—Hides rows of alarms that contain the same severity for each profile.
10.4.6 Applying Alarm Profiles
In CTC node view, the Alarm Behavior window displays alarm profiles for the node. In card view, the
Alarm Behavior window displays the alarm profiles for the selected card. Alarm profiles form a
hierarchy. A node alarm profile applies to all cards in the node except cards that have their own profiles.
A card alarm profile applies to all ports on the card except ports that have their own profiles.
At the node level, you can apply profile changes on a card-by-card basis or set a profile for the entire
node. At the card view, you can apply profile changes on a port-by-port basis or set alarm profiles for all
ports on that card. Figure 10-2 shows an ONS 15310-MA SDH 15310E-CTX-K9 card alarm profile.
Figure 10-2 Alarm Profile for a 15310-MA SDH 15310E-CTX-K9 Card
10.5 Alarm Suppression
The following sections explain alarm suppression features for the ONS 15310-MA SDH.