York YHJD18 thru 60 Heat Pump User Manual


 
571209-YTG-C-1012
Johnson Controls Unitary Products 5
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
YHJD42S41S4
AHE48D 24.5 1385 40.5 33.2 14.00 12.00
AHR48D 24.5 1320 39.5 29.6 13.00 11.00
AHV48D 24.5 1300 39.5 30.2 13.75 11.50
AV*48 24.5 1385 42.0 32.6 14.50 12.00
AV*60 24.5 1360 42.0 32.6 14.50 12.00
MV16C 21.0 FC60C 1400 40.0 30.0 13.50 11.75
MV20D 24.5 FC/MC60D 1400 42.0 32.4 14.00 12.00
MX16C 21.0 FC60C 1420 41.5 32.2 14.50 12.00
MX20D 24.5 FC/MC60D 1470 41.5 32.2 14.50 12.00
YHJD48S41S4
AHE48D 24.5 1635 44.0 33.2 14.00 12.00
AHE60D 24.5 1565 45.0 34.4 14.50 12.00
AHR48D 24.5 1610 43.5 32.8 13.00 11.00
AHR60D 24.5 1620 44.0 33.8 13.25 11.35
AHV48D 24.5 1585 44.5 33.2 14.50 12.00
AHV60D 24.5 1570 44.5 34.0 14.50 12.00
AV*48 24.5 1625 45.0 34.4 14.50 12.00
AV*60 24.5 1560 45.0 34.6 14.50 12.00
MV16C 21.0 FC60C 1625 44.5 34.2 14.50 12.00
MV20D 24.5 FC/MC60D 1600 44.5 33.8 14.50 12.00
MV20D 24.5 FC/MC62D 1630 45.5 34.4 14.50 12.00
MX16C 21.0 FC60C 1630 45.0 34.4 14.50 12.00
MX20D 24.5 FC/MC60D 1585 45.5 34.6 14.50 12.00
MX20D 24.5 FC/MC62D 1605 45.0 34.4 14.50 12.00
YHJD60S41S5
AHE60D 24.5 1950 58.0 41.50 13.00 11.00
AHR60D 24.5 1835 58.0 41.00 14.00 12.00
AHV60D 24.5 1635 57.5 39.0 13.75 11.80
MV20D 24.5 FC/MC62D 1855 58.0 41.5 13.75 11.80
MV20D 24.5 FC64D 1855 57.0 43.0 13.25 11.35
MX20D 24.5 FC/MC62D 1795 58.0 41.0 14.00 12.00
MX20D 24.5 FC64D 1795 57.0 42.5 13.75 12.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80 °F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95 °F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
13 SEER HP WITH AIR HANDLERS