COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during
the same period.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
— = Not Applicable.
YHJD48S41S4
Y*9C*C20 FC/MC62D 45.5 3.56 3.74 27.2 2.78 2.87 8.20
Y*9C*C20 FC/PC60C 46.0 3.62 3.72 27.4 2.80 2.87 8.20
Y*9C*C20 UC60C 45.5 3.58 3.72 27.2 2.78 2.87 8.20
Y*9C*D20 FC/MC/PC60D 46.0 3.64 3.70 27.2 2.80 2.85 8.20
Y*9C*D20 FC/MC62D 45.5 3.60 3.70 27.2 2.80 2.85 8.20
Y*9C*D20 UC60D 45.5 3.60 3.70 27.0 2.78 2.85 8.20
YHJD60S41S5
T*(8,L)V*C20 FC/MC62D 58.0 3.38 5.03 39.0 2.66 4.30 8.15
T*(8,L)V*C20 FC64D 58.0 3.36 5.06 41.0 2.78 4.32 8.05
T*(8,L)X*C20 FC/MC62D 58.0 3.44 4.94 38.5 2.70 4.18 8.20
T*(8,L)X*C20 FC64D 58.0 3.36 5.06 39.5 2.82 4.10 8.10
T*9(C,V)*C20 FC/MC62D 58.0 3.36 5.06 39.0 2.64 4.33 8.10
T*9(C,V)*C20 FC64D 58.0 3.30 5.15 40.0 2.76 4.25 8.15
T*9(C,V)*D20 FC/MC62D 58.0 3.38 5.03 39.0 2.66 4.30 8.15
T*9(C,V)*D20 FC64D 58.0 3.30 5.15 40.0 2.76 4.25 8.15
T*9X*C20 FC/MC62D 58.0 3.44 4.94 38.5 2.70 4.18 8.20
T*9X*C20 FC64D 58.0 3.32 5.12 39.5 2.78 4.16 8.20
T*9X*D20 FC/MC62D 58.0 3.42 4.97 38.5 2.68 4.21 8.15
T*9X*D20 FC64D 58.0 3.36 5.06 40.0 2.80 4.19 8.20
Y*(8,L)C*C20 FC/MC62D 58.0 3.38 5.03 39.0 2.66 4.30 8.15
Y*(8,L)C*C20 FC64D 58.0 3.36 5.06 41.0 2.78 4.32 8.05
Y*9C*C20 FC/MC62D 58.0 3.36 5.06 39.0 2.64 4.33 8.10
Y*9C*C20 FC64D 58.0 3.30 5.15 40.5 2.74 4.33 8.10
Y*9C*D20 FC/MC62D 58.0 3.38 5.03 39.0 2.66 4.30 8.15
Y*9C*D20 FC64D 58.0 3.30 5.15 40.0 2.76 4.25 8.15
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and
no supplemental electric heat operation.
3. High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
MODEL
FURNACE
MODEL
COIL
1
MODEL
HEATING
2
47 F 17 F HSPF
MBH COP KW MBH COP KW STD
13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
3