York YHJD18 thru 60 Heat Pump User Manual


 
571209-YTG-C-1012
38 Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO YHJD24S41S4
EVAPORATOR COIL MODEL NO AHP30
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
600 800 1000
MBH COP KW MBH COP KW MBH COP KW
60
60 28.3 3.8 2.20 27.5 3.7 2.15 26.7 3.7 2.10
70 27.5 3.5 2.27 26.9 3.5 2.23 26.4 3.5 2.19
80 26.7 3.3 2.35 26.3 3.3 2.32 26.0 3.3 2.28
47
60 24.9 3.6 2.03 24.5 3.6 2.01 24.1 3.6 1.98
70 23.8 3.4 2.08 24.0 3.4 2.06 24.1 3.4 2.10
80 22.7 3.1 2.14 23.4 3.2 2.15 24.1 3.3 2.17
40
60 23.1 3.5 1.94 22.7 3.5 1.93 22.4 3.4 1.92
70 21.9 3.2 1.98 22.0 3.2 1.99 22.0 3.2 1.99
80 20.7 3.0 2.03 21.2 3.0 2.05 21.7 3.1 2.07
30
60 19.0 3.1 1.79 19.6 3.2 1.82 20.1 3.2 1.84
70 17.7 2.8 1.83 18.6 2.9 1.87 19.4 3.0 1.90
80 16.4 2.6 1.87 17.6 2.7 1.92 18.7 2.8 1.96
17
60 13.8 2.5 1.64 13.9 2.4 1.73 14.1 2.3 1.83
70 13.3 2.4 1.65 13.8 2.3 1.73 14.3 2.3 1.82
80 12.5 2.2 1.68 13.4 2.2 1.75 14.3 2.3 1.81
10
60 12.7 2.4 1.58 11.1 2.0 1.61 9.5 1.7 1.64
70 11.1 2.0 1.59 10.7 1.9 1.64 10.3 1.8 1.69
80 9.4 1.7 1.61 10.2 1.8 1.68 11.1 1.9 1.75
NOTE: ALL CAPACITIES ARE NET, WITH INDOOR FAN HEAT ALREADY DEDUCTED. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Air Handlers Coils MBH COP KW
FC/MC/PC32 1.00 1.00 1.00
FC/MC/PC35 1.00 1.00 1.00
FC/MC/PC37 1.01 1.01 1.00
FC/MC/PC43 1.01 1.01 1.00
AHE24B 0.97 1.05 0.92
AHE30B 0.97 1.05 0.92
AHR24B 0.97 0.99 0.97
AHV24B 0.94 1.02 0.93
AHV30B 0.96 1.04 0.93
AHV36C 0.98 1.07 0.91
AV*36 0.96 1.06 0.90
MV12B FC/MC35B 0.98 1.06 0.92
MV12B FC/MC43B 0.98 1.07 0.92
MX12B FC/MC35B 0.97 1.08 0.90
MX12B FC/MC43B 0.96 1.06 0.91
Furnaces Coils MBH COP KW
T*(8,L)V*A12 FC/MC/PC32A 0.96 1.03 0.93
T*(8,L)V*A12 FC/MC/PC37A 0.98 1.07 0.92
T*(8,L)V*B12 FC/MC/PC35B 0.98 1.05 0.93
T*(8,L)V*B12 FC/MC/PC43B 0.98 1.07 0.92
T*(8,L)V*C16 FC/MC/PC35C 0.98 1.06 0.92
T*(8,L)V*C16 FC/MC/PC43C 0.98 1.08 0.90
T*(8,L)V*C20 FC/MC/PC35C 0.95 1.04 0.92
T*(8,L)V*C20 FC/MC/PC43C 0.96 1.05 0.91
T*(8,L)X*A12 FC/MC/PC32A 0.98 1.07 0.91
T*(8,L)X*A12 FC/MC/PC37A 0.98 1.11 0.89
T*(8,L)X*B12 FC/MC/PC35B 0.97 1.07 0.90
T*(8,L)X*B12 FC/MC/PC43B 0.98 1.11 0.89
T*(8,L)X*C16 FC/MC/PC35C 0.97 1.08 0.90
T*(8,L)X*C16 FC/MC/PC43C 0.98 1.11 0.89
T*(8,L)X*C20 FC/MC/PC35C 0.98 1.07 0.91
T*(8,L)X*C20 FC/MC/PC43C 0.98 1.08 0.90
T*9V*A10 FC/MC/PC32A 0.98 1.02 0.96
T*9V*A10 FC/MC/PC37A 0.99 1.04 0.96
T*9(C,V)*B12 FC/MC/PC35B 0.98 1.04 0.94
T*9(C,V)*B12 FC/MC/PC43B 0.98 1.06 0.92
T*9(C,V)*C16 FC/MC/PC35C 0.98 1.06 0.93
T*9(C,V)*C16 FC/MC/PC43C 0.98 1.07 0.92
T*9(C,V)*C20 FC/MC/PC35C 0.95 1.03 0.92
T*9(C,V)*C20 FC/MC/PC43C 1.00 1.09 0.92
T*9X*A10 FC/MC/PC32A 0.96 1.01 0.95
T*9X*A10 FC/MC/PC37A 0.98 1.04 0.94
T*9X*B12 FC/MC/PC35B 0.98 1.07 0.91
T*9X*B12 FC/MC/PC43B 0.98 1.09 0.90
T*9X*C16 FC/MC/PC35C 0.98 1.07 0.91
T*9X*C16 FC/MC/PC43C 0.98 1.09 0.90
T*9X*C20 FC/MC/PC35C 0.98 1.06 0.92
T*9X*C20 FC/MC/PC43C 0.98 1.08 0.90
Y*(8,L)C*A12 FC/MC/PC32A 0.96 1.03 0.93
Y*(8,L)C*A12 FC/MC/PC37A 0.98 1.07 0.92
Y*(8,L)C*B12 FC/MC/PC35B 0.98 1.05 0.93
Y*(8,L)C*B12 FC/MC/PC43B 0.98 1.07 0.92
Y*(8,L)C*C16 FC/MC/PC35C 0.98 1.06 0.92
Y*(8,L)C*C16 FC/MC/PC43C 0.98 1.08 0.90
Y*(8,L)C*C20 FC/MC/PC35C 0.95 1.04 0.92
Y*(8,L)C*C20 FC/MC/PC43C 0.96 1.05 0.91
Y*9C*B12 FC/MC/PC35B 0.98 1.04 0.94
Y*9C*B12 FC/MC/PC43B 0.98 1.06 0.92
Y*9C*C16 FC/MC/PC35C 0.98 1.06 0.93
Y*9C*C16 FC/MC/PC43C 0.98 1.07 0.92
Y*9C*C20 FC/MC/PC35C 0.95 1.03 0.92
Y*9C*C20 FC/MC/PC43C 1.00 1.09 0.92
Furnaces Coils MBH COP KW