York YHJD18 thru 60 Heat Pump User Manual


 
571209-YTG-C-1012
Johnson Controls Unitary Products 35
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO. YHJD60S41S5
INDOOR COIL MODEL NO. AHX60
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM 1800 2000 2200
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C.
57.5 60.5 60.5 66.0 72.0 59.4 61.6 61.6 67.1 73.0 61.2 62.7 62.6 68.2 74.0
S.C.
57.1 52.5 44.9 44.2 35.6 58.9 55.6 46.8 46.2 36.7 60.8 58.6 48.8 48.2 37.7
KW
3.59 3.62 3.62 3.68 3.75 3.68 3.70 3.71 3.76 3.83 3.78 3.79 3.79 3.85 3.92
75
T.C.
55.4 57.7 57.7 63.0 68.8 57.1 58.6 58.6 64.0 69.7 58.8 59.6 59.5 65.0 70.7
S.C.
55.0 51.3 43.6 42.9 34.2 56.7 54.0 45.5 44.9 35.3 58.4 56.8 47.4 46.8 36.4
KW
4.02 4.05 4.05 4.11 4.18 4.11 4.13 4.13 4.19 4.27 4.21 4.22 4.21 4.28 4.36
85
T.C.
53.3 54.8 54.9 60.1 65.6 54.9 55.7 55.6 61.0 66.5 56.5 56.5 56.3 61.8 67.4
S.C.
52.9 50.0 42.2 41.6 32.8 54.5 52.5 44.1 43.6 33.9 56.1 54.9 46.1 45.5 35.0
KW
4.45 4.47 4.47 4.54 4.61 4.55 4.56 4.56 4.62 4.70 4.64 4.64 4.64 4.71 4.79
95
T.C.
51.2 51.9 52.0 57.1 62.4 52.6 52.7 52.6 57.9 63.2 54.1 53.5 53.1 58.6 64.0
S.C.
50.8 48.8 40.9 40.4 31.4 52.3 50.9 42.8 42.2 32.5 53.7 53.1 44.7 44.1 33.7
KW
4.89 4.90 4.90 4.97 5.05 4.98 4.98 4.98 5.06 5.14 5.07 5.07 5.06 5.14 5.23
105
T.C.
48.5 48.3 48.6 53.4 58.5 49.8 49.5 49.1 54.0 59.1 51.2 50.6 49.5 54.6 59.7
S.C.
48.1 46.6 39.4 38.8 29.9 49.5 48.4 41.3 40.7 31.0 50.8 50.2 43.1 42.6 32.1
KW
5.43 5.42 5.43 5.50 5.58 5.52 5.52 5.51 5.59 5.67 5.62 5.62 5.60 5.68 5.76
115
T.C.
45.8 44.8 45.2 49.6 54.6 47.0 46.3 45.5 50.1 55.0 48.3 47.7 45.9 50.6 55.5
S.C.
45.5 44.5 37.9 37.3 28.5 46.7 45.9 39.7 39.2 29.5 47.9 47.4 41.6 41.1 30.5
KW
5.97 5.95 5.97 6.04 6.12 6.07 6.06 6.05 6.12 6.21 6.17 6.16 6.13 6.21 6.29
125
T.C.
43.1 41.2 41.7 45.9 50.7 44.2 43.0 42.0 46.2 50.9 45.4 44.9 42.3 46.5 51.2
S.C.
42.8 41.2 36.3 35.7 27.0 43.9 43.0 38.2 37.6 28.0 45.0 44.5 40.0 39.5 28.9
KW
6.51 6.48 6.50 6.57 6.65 6.62 6.59 6.58 6.66 6.74 6.72 6.71 6.66 6.74 6.82
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Air Handlers Coils T.C. S.C. KW
FC/MC62 0.99 0.97 0.96
FC64 0.98 1.01 0.99
AHE60D 1.01 0.97 0.94
AHR60D 1.00 1.00 1.00
AHV60D 0.99 0.92 0.93
MV20D FC/MC62D 1.00 0.98 0.94
MV20D FC64D 0.98 1.02 0.97
MX20D FC/MC62D 1.01 0.97 0.93
MX20D FC64D 0.98 1.01 0.94
Furnaces Coils T.C. S.C. KW
T*(8,L)V*C20 FC/MC62D 0.98 0.93 0.94
T*(8,L)V*C20 FC64D 0.98 1.01 0.98
T*(8,L)X*C20 FC/MC62D 0.99 0.95 0.91
T*(8,L)X*C20 FC64D 0.97 0.97 0.93
T*9(C,V)*C20 FC/MC62D 0.98 0.93 0.94
T*9(C,V)*C20 FC64D 0.96 0.96 0.95
T*9(C,V)*D20 FC/MC62D 0.99 0.93 0.94
T*9(C,V)*D20 FC64D 0.96 0.95 0.95
T*9X*C20 FC/MC62D 0.99 0.95 0.91
T*9X*C20 FC64D 0.96 0.95 0.93
T*9X*D20 FC/MC62D 0.99 0.95 0.92
T*9X*D20 FC64D 0.97 0.96 0.94
Y*(8,L)C*C20 FC/MC62D 0.98 0.93 0.94
Y*(8,L)C*C20 FC64D 0.98 1.01 0.98
Y*9C*C20 FC/MC62D 0.98 0.93 0.94
Y*9C*C20 FC64D 0.96 0.96 0.96
Y*9C*D20 FC/MC62D 0.99 0.93 0.94
Y*9C*D20 FC64D 0.96 0.95 0.95