18 Johnson Controls Unitary Products
TABLE 10: ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 38.0 40.0 43.5 45.5 50 50 50 50
2TP04520925 6.8 18.9 38.0 40.0 43.5 45.5 50 50 50 50
2TP04521825 13.5 37.5 54.6 57.1 61.5 64.0 60 60 70 70
2TP04522425 18 50.0 70.2 72.7 77.1 79.6 80 80 80 80
2TP04523625 25.5 70.8 96.2 98.7 103.1 105.6 100 100 110 110
None -- -- 38.0 40.0 43.5 45.5 50 50 50 50
2TP04520925 9 21.7 38.0 40.0 43.5 45.5 50 50 50 50
2TP04521825 18 43.3 61.9 64.4 68.8 71.3 70 70 70 80
2TP04522425 24 57.7 79.9 82.4 86.8 89.3 80 90 90 90
2TP04523625 34 81.8 110.0 112.5 116.9 119.4 110 125 125 125
None -- -- 20.7 21.7 22.9 23.9 25 25 25 30
2TP04520946 9 11.3 20.7 21.7 22.9 23.9 25 25 25 30
2TP04521846 18 22.6 30.9 32.2 33.7 34.9 35 35 35 35
2TP04522446 24 30.1 40 41.2 42.7 44 40 45 45 45
2TP04523646 34 42.7 55 56.2 57.7 59 60 60 60 60
None -- -- 15.1 16.3 16.9 18.1 20 20 20 20
2TP04520958 9 9.0 15.1 16.3 16.9 18.1 20 20 20 20
2TP04521858 18 18.1 24.7 26.2 26.9 28.4 25 30 30 30
2TP04522458 24 24.1 31.9 33.4 34.1 35.6 35 35 35 40
2TP04523658 34 34.1 43.9 45.4 46.1 47.6 45 50 50 50
* Maximum HACR breaker of the same AMP size is applicable.
12.8 110.0 1.5 6.2 8.2 5.5 0.0
12.8 110.0 1.5
7.1 54.0 0.8
5.1 44.0
6.2 8.2
3.1 4.1
0.6 2.4 3.6
5.5 0.0
2.2 0.0460
575
1.8 0.0
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Supply
Blower
Motor FLA
Pwr
Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Voltage
Compressors
OD Fan
Motors
208
230
TABLE 11: ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 48.0 50.0 53.5 55.5 60 60 60 60
2TP04520925 6.8 18.9 48.0 50.0 53.5 55.5 60 60 60 60
2TP04521825 13.5 37.5 67.1 69.6 74.0 76.5 70 70 80 80
2TP04522425 18 50.0 82.7 85.2 89.6 92.1 90 90 90 100
2TP04523625 25.5 70.8 108.7 111.2 115.6 118.1 110 125 125 125
None -- -- 48.0 50.0 53.5 55.5 60 60 60 60
2TP04520925 9 21.7 48.0 50.0 54.2 56.7 60 60 60 60
2TP04521825 18 43.3 74.4 76.9 81.3 83.8 80 80 90 90
2TP04522425 24 57.7 92.4 94.9 99.3 101.8 100 100 100 110
2TP04523625 34 81.8 122.5 125.0 129.4 131.9 125 125 150 150
None -- -- 25.7 26.7 27.9 28.9 30 30 30 35
2TP04520946 9 11.3 25.7 26.7 27.9 28.9 30 30 30 35
2TP04521846 18 22.6 37.2 38.4 39.9 41.2 40 40 40 45
2TP04522446 24 30.1 46.2 47.5 49 50.2 50 50 50 60
2TP04523646 34 42.7 61.2 62.5 64 65.2 70 70 70 70
None -- -- 19.1 20.3 20.9 22.1 20 25 25 25
2TP04520958 9 9.0 19.1 20.3 21.1 22.6 20 25 25 25
2TP04521858 18 18.1 29.7 31.2 31.9 33.4 30 35 35 35
2TP04522458 24 24.1 36.9 38.4 39.1 40.6 40 40 40 45
2TP04523658 34 34.1 48.9 50.4 51.1 52.6 50 60 60 60
*
12.8 110.0 1.5230
1.5 5.5 10.06.2 8.2208 110.0
460
575
12.8
Voltage
Compressors
OD Fan
Motors
Supply
Blower
Motor FLA
Pwr
Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Maximum HACR breaker of the same AMP size is applicable.
6.2 8.2 5.5 10.0
7.1 54.0 0.8 3.1 4.1 2.2 5.0
5.1 44.0 0.6 2.4 3.6 1.8 4.0