Yeoman YMMB Stove User Manual


 
5
USER INSTRUCTIONS
AIRWASH AND PRIMARY AIR CONTROLS
3
PR9025
Open Close
Open Close
Airwash Control
Primary Air Control
SECONDARY AIR CONTROLS
4
PR9026
Secondary Air Control
In - Closed
Out - Open
DOOR HANDLE
1.13 Use a protected gloved hand to operate.
1.14 Rotate clockwise and pull to open.
Warning: Do not force the handle
as damage may occur
(see Diagram 5).
DO NOT OPEN THE DOOR WITH BARE HANDS
5
Turn handle
clockwise
to open
PR9027
WARNING
Properly installed, operated and maintained, this
appliance will not emit fumes into the room. Occasional
fumes from de-ashing and refuelling may occur.
Persistent fume emission is potentially dangerous and
must not be tolerated.
If fume emission does persist:
Open doors and windows to ventilate the room.
Leave the room.
Allow fire to burn out and safely dispose of fuel from
the appliance.
Check for chimney blockage and clean if required.
Do not attempt to relight until the cause of the emission
has been identified and corrected
If necessary seek expert advice.
All open flued appliances can be affected by temporary
atmospheric conditions which may allow fumes to
enter the house. Because of this an electronic carbon
monoxide detector conforming to the latest edition
of BSEN50292 must be fitted in the same room as
the appliance. The existence of an alarm must not be
considered a substitute for ensuring regular servicing
and maintenance of the appliance and chimney system.
If the alarm sounds follow the instructions given under
Warning above.
2. USING THE APPLIANCE FOR THE
FIRST TIME
2.1 To allow the appliance to settle, and fixing glues and paint
to fully cure, operate the appliance at a low temperature for
first few days.
2.2 Do not touch the paint during the first period of use.
2.3 During this time the appliance may give off some
unpleasant odours. Keep the room well ventilated to avoid
a build-up of fumes.
2.4 Please be aware that, during use, rope seals may discolour.
This is normal.