13. CHIMNEY SWEEPING
13.1 To maintain safe and efficient use of the appliance, the
chimney/flue must be inspected and swept at least once a
year by a qualified chimney sweep**.
If the appliance is used continuously throughout the year,
or it is used to burn wood or smokeless fuel, more frequent
sweeping is recommended.
The best time to have the chimney swept is at the start of
the heating season.
The above applies even if burning smokeless fuels.
13.2 The chimney, any connecting flue pipe and the appliance
flue ways, if incorporated, must be regularly cleaned.
13.3 Ensure adequate access for cleaning where it is not possible
to sweep through the chimney.
13.4 If the chimney is believed to have previously served an
open fire it must be swept a second time within a month of
regular use after installation.
14. CARE OF STOVE
Yeoman has a range of cleaning and maintenance products
and accessories to keep your appliance in good working
order. Your Yeoman retailer can advise you on suitable
items for your stove and provide genuine spare parts such
asreplacementglass,doorsealingropeandrebricks.
View the extensive range at www.yeoman-stoves.co.uk by
clicking on Accessories. In addition, an annual service by a
competent engineer is recommended to keep your stove in
the best possible condition.
USER INSTRUCTIONS
11. GENERAL CLEANING
11.1 Clean and inspect the appliance regularly, especially in
periods of heavy use. Regular cleaning and maintenance
will help give many years of safe use.
Allow appliance to cool thoroughly to avoid risk of burns.
Clean regularly, according to level of use.
Remove the ash completely (see User Instructions,
Section 7).
Check the internal components for damage. Do not use
the appliance if any parts are broken or damaged. Replace
damaged parts with genuine Yeoman replacement parts to
keep the appliance in safe, efficient working order.
Check for obvious build up of soot, ash or debris above the
flue baffle(s) (these can be found in the upper part of the
firebox). Use a torch if necessary.
If there are any signs of a build up of debris above the flue
baffle(s) either:
Arrange for the chimney to be swept (see User
Instructions, Section 13).
Remove the baffle and clear the debris (see Installation
Instructions, Section 4).
To refresh painted finishes use Midnight black paint.
Check that the door shuts properly and creates an effective
seal. Leaking door seals prevent the appliance working
properly.
Do not use aerosol sprays near an operating appliance.
12. CLEANING GLASS
Keep the glass clean with correct use of the Airwash system
and good quality fuel.
12.1 Sometimes additional cleaning may be required.
This can be done as follows:
Allow appliance to cool fully. Do not clean hot glass.
Use a soft cloth and suitable cleaner.
12.2 Do not use cleaning agents that have a high alkaline
content, for example Stovax Gel Cleaner, on appliances
with painted glass such as the Studio, View or CL. These
are abrasive cleaning agents that are designed to be used
with heavily stained clear glass. Use Stovax Glass Cleaner
(Stovax No.4103) on more delicate surfaces.
Do not use acidic cleaners on printed glass.
12.3 Before re-lighting the appliance dry the glass fully.
**This should be done by a HETAS Approved Chimney
Sweep (UK only) see page 26 / INFO registered (Republic
of Ireland only) who will issue you with a certificate.