Yeoman YMMB Stove User Manual


 
20
INSTALLATION INSTRUCTIONS
2. REMOVAL OF THE DOOR
2.1 To remove the door:
Using a 5mm A/F Hey Key remove the door by opening,
removing the 4 bolts and lifting the door free of the
appliance body.
PR7084
4 Bolts
3. REMOVAL OF THE LOG GUARD
3.1 To remove the log guard:
Lift log guard clear of the supporting brackets.
Rotate to clear the sides of the door opening.
Do not use appliance without the log guard in position.
4. REMOVAL OF THE BAFFLE
4.1 The appliance is fitted with a baffle in the top of the firebox
to maintain efficient combustion.
4.2 Allow the appliance to cool fully before removing baffle
system.
PR9040
Baffle
5
4.3 Remove the log guard from the appliance to give access to
the firebox.
1.5 Reposition clamps by hand through the flue opening and
tighten using a 13A/F spanner. Check the clamps are
against the throat forming lintel as shown in Diagram 3.
PR9039
3
Reach through door
and up and out
of flue opening to
adjust clamps
Throat
forming lintel
Clamp
Milner
brick
ø 16mm
Rope seal
1.6 Check the ø16mm rope seal is still in the correct position.
The appliance must be sealed against the face of the
chimney breast / fire surround and at the hearth to the base
of the appliance. This seal must be made air-tight with the
use of heat resistant sealant such as fire cement or very
high temperature flexible sealer.
1.7 Drill 2 appropriately placed ø10mm holes in the Milner
hearth. Secure the stove to the hearth via the holes shown
in Diagram 4 using metal wall plugs and bolts.
PR9034
4
Attach stove to
hearth via holes
in floor of stove
1.8 Refit all internal components.