Windsor 30 SP Vacuum Cleaner User Manual


 
6 English
ducting material to prevent the hand chain
from shorting in cell connectors or termi-
nals. A properly insulated spreader bar
shall be used with any overhead hoist.
Reinstalled or new batteries shall meet or
exceed the battery type marked on the unit.
Reinstalled batteries shall be positioned
properly and secured in the unit.
A carboy tilter or siphon shall be provided
where acid in carboys is used. Where dilut-
ing concentrated sulfuric acid to make up
elektrolyte, the acid ALWAYS shall be add-
ed to the water – not reverse. Battery main-
tenance personnel shall wear protective
clothing such as eye protection, long
sleeves, and gloves.
Exception: Removal and replacement of
batteries shall not require the use of protec-
tive clothing.
Electrical installations shall be in accor-
dance with NFPA 70, National electric
code, and any local ordinances.
Trained and authorized personnel shall
change or charge batteries.
The powered floor scrubber shall be posi-
tioned properly and brakes shall be applied
before attempting to change or charge bat-
teries.
Where charging batteries, the vent caps
shall be kept in place to avoid electrolyte
spray. Care shall be taken to ensure that
vent caps are functionning. The battery (or
compartment) cover(s) shall be open to dis-
sipate heat and gas.
Smoking shall be prohibited in the charging
area.
Precautions shall be taken to prevent open
flames, sparks, or electric arcs in battery-
charging areas.
Tools and other metallic objects shall be
kept away from the tops of uncovered bat-
teries.
Dear Customer,
Please read and comply with
these instructions prior to the
initial operation of your appli-
ance. Retain these operating instructions
for future reference or for subsequent pos-
sessors.
Safety instructions 6
Function 6
Intended Use 6
Environmental Protection, Disposal 6
Operating and Functional Elements 7
Before Startup 8
Operation 9
Maintenance and care 12
Faults 12
Accessories 15
Technical Specifications 16
Charger for package model 16
The machine has been approved for use on
surfaces with gradients of up to 10%.
The machine may only be used when the
dirty water tank has been tilted forward
and all the lids are closed.
Safety devices serve to protect the user and
must not be rendered inoperational or their
functions bypassed.
Pull the battery plug to put all functions out
of operation immediately.
The safety button switches off the drive mo-
tor with a delay of 1.5 seconds if the opera-
tor leaves his seat when the machine is
running.
The following symbols are used in this op-
erating manual:
ƽ Danger
indicates an immediate threat of danger.
Failure to observe the instruction may result
in death or serious injuries.
Warning
indicates a possibly dangerous situation.
Failure to observe the instruction may result
in light injuries or damage to property.
Note
indicates useful tips and important informa-
tion.
The appliance is used for the wet cleaning
or polishing of level floors.
You can adjust the machine to suit the
cleaning task by modifying the settings
for water quantity, contract pressure
and the speed of the brushes, the quan-
tity of cleaning agent as well as the driv-
ing speed.
A working width of 750 mm (27.5 in) and
a capacity of 140 l (37 gal) each of the
fresh water and dirty water tank enable
effective cleaning even if the machine is
used for long durations.
The device is self-moving; the drive mo-
tor is fed by a battery.
The batteries can be charged using a
charger connected to a 120 V socket.
Depending on the package type, battery
and charger are included.
Note
The appliance can be equipped with vari-
ous accessories depending on the cleaning
task.
Use this appliance only as directed in these
operating instructions.
The appliance may only be used for the
cleaning of hard surfaces that are not
sensitive to moisture and polishing op-
erations.
The application temperature ranges
from +5°C to +40°C (41°F1 to 104°F).
The appliance is not suited for the
cleaning of frozen grounds (e.g. in cold
stores).
The appliance may only be equipped
with original accessories and spare
parts.
The appliance has been developed for
cleaning floors - floors inside rooms and
roofed areas. With respect to other ap-
plications the usage of alternative
brushes must be checked.
The appliance is not intended for the
cleaning of public traffic routes.
The machine should not be used on sur-
faces that are sensitive to pressure.
Please consider the allowed load per
surface unit of the floor. Details of load
per surface unit can be found in the
technical data.
The appliance is not suited for the use in
potentially explosive environments.
The machine should not be used to
suck in flammable gases, undiluted ac-
ids or solvents.
This includes petrol, thinning agents or
hot oil that can form an explosive mix-
ture when it comes in contact with
sucked air. Do not use acetone, undilut-
ed acids and solvents as they are ag-
gressive towards the materials from
which the appliance is made.
Contents
Safety instructions
Safety Devices
Battery plug/ Emergency-stop
Safety button
Symbols
Function
Proper use
Environmental Protection,
Disposal
The packaging materials are
recyclable. Please do not throw
packaging in the domestic
waste but pass it on for recy-
cling.
Old units contain valuable recy-
clable materials. Batteries, oil
and similar substances may
not be released into the envi-
ronment. Therefore please dis-
pose of old units through
suitable collection systems.