Windsor 30 SP Vacuum Cleaner User Manual


 
14 English
Faults without display on the console
Fault Remedy
Appliance cannot be started Insert battery plug.
Set main switch to “1”.
Check fuse F1, replace if required. *
Check battery; charge it if required.
Insufficient water quantity Check fresh water level, refill tank if necessary.
Check hoses for blockages; clean if required.
Clean the fresh water filter.
Insufficient vacuum perfor-
mance
Clean the seals between dirty water reservoir and cover and check for tightness, replace if required.
Clean the flat-fold filters at the suction support of the suction turbine.
Clean the squeegee blades on the squeegee tool, replace if required
Check suction hose for blockages; clean if required.
Check the suction hose for tightness; replace if required.
Check if the cover on the dirty water discharge hose is closed
Check the setting of the squeegee tool.
Insufficient cleaning result Set/ adjust contact pressure.
Check the brushes for wear, replace if required.
Brushes do not turn Reduce contact pressure.
Check if foreign matters block the brushes; remove foreign matter if required.
Optional overall lamp and/or
working lamp is not functioning
Check fuse F4, replace if required. *
* The fuses are located in the flat insertion sockets on the wiring plate and can be accessed by opening the front panel.