Whirlpool 318686-000 Water Heater User Manual


 
4
2 1/2” Max
Pipe to
adequate
drain
At least 2” inches greater than
the diameter of the water
heater.
Figure 1
Figure 2
Residential Garage
Installation
Vehicle
Stop
Drain
Metal Drain Pan
GRID
EMABLED
VACATION
STANDARD
ENERGY
SMART
°F/°C
F
Location Requirements
Site location
Select a location near the center of the water piping
system. It must be installed indoors and in a vertical
position on a level surface, in an area where water
leakage will not cause consequential damage.
The water heater should be located in an area not
subject to freezing temperatures. Water heaters located
in unconditioned spaces (i.e., attics, garages, base-
ments, etc.) may require the water piping and drain
piping to be insulated to protect against freezing. The
drain and controls must be easily accessible for opera-
tion and service.
Keep combustibles such as boxes, magazines, clothes,
etc., away from the water heater area.
Do not use this water heater in conjunction with a spa or
hot tub.
IMPORTANT: The water heater should be located in
an area where leakage of the tank or connections will
not result in damage to the area adjacent to the water
heater or to lower floors of the structure. Due to the
normal corrosive action of the water, the tank will
eventually leak after an extended period of time.
Also, any external plumbing leak, including those
from improper installation, may cause early
failure of the water tank due to corrosion if not
repaired. If the homeowner is uncomfortable with
making the repair, a qualified person should be
contacted. A suitable metal drain pan should be
installed under the water heater as shown below. This
metal drain pan is to protect the property from damage
which may occur from normal condensate formation
on the tank or leaks in the tank and pipe connections.
The metal drain pan must limit the water level to a
maximum depth of 2-1/2 inches and be two inches
wider than the heater and piped to an adequate drain.
Locate the water heater near a
suitable indoor drain. Outdoor drains are subject to
freezing temperatures which can obstruct the drain
line. The piping should be at least 3/4”ID and pitched
for proper drainage.
Under no circumstance will the manufacturer or
seller of this water heater be held liable for any
water damage that is caused by your failure to
follow these instructions.
NOTE: Local codes and requirements in your area may
require the water heater to be installed such that the
bottom element is elevated from the floor at least 18
inches.
NOTE: The water heater shall be located so it is not
subject to physical damage by moving vehicles or area
flooding.
State of California
NOTE: The water heater must be braced, anchored, or
strapped to avoid moving during an earthquake. Contact
local utilities for code requirements in your area or call
1-877-817-6750 and request instructions.