TROUBLESHOOTING‐continued
DoorGlasshassootbuildupatafastrateandflameislazywithblacktips.
Theventpipe(includingairintake)maybedirtyorpartiallyblockedrestrictingairflowtotheunit.
Theintakebutterflyvalvemightbesetattoolowposition.(seepage15)
Burnpotholesareblocked.Lettheunitcoolandcleanburnpotandburnpotliner(besuretofollow
instructionsfordisposalofashesfoundonpage29)
Circuitboardmalfunction.Timethefuelfeedlightateachsetting(after thestovehascompletedthe
initial "StartUp" sequence. Checkthe timing against the timing chart (foundbelow), if the auger
motorrunsconstantlythereisaproblemwiththecircuitboard
Combustionblowerisnotoperating.Checktheexhaustblowerisoperating,ifnotbypasstheexhaust
temperatureswitch;ifthemotoroperatesreplacetheexhausttemperatureswitch.Iftheexhaust
blowerstilldoesnotworkapply120voltsdirectlytotheexhaustblowermotor,ifthemotordoesnot
workreplacetheexhaustblowermotor.
Poorfuelquality.Thetype ofpelletsbeingusedmaybeofpoorquality,ifpossibletryadifferent
brandofpellets(refertofueltypeinformationonpage3).
ControlBoardTiming
Heatlevel1
Augeron2seconds Augeroff5seconds
Heatlevel2 Augeron3seconds Augeroff3seconds
Heatlevel3 Augeron5seconds Augeroff3seconds
Heatlevel4 Augeron7seconds Augeroff3seconds
Heatlevel5 Augeron10seconds Augeroff3seconds