11
OPERATINGINSTRUCTIONS‐continued
theAugerfeedratewillhelpkeeptheflamesfromextinguishingontheminimumheatlevelsetting.Youcanalso
usetheAUGERTRIMbuttontolowerheatoutputontheminimumheatlevelsetting:
Depressand releasethe AUGERTRIM button untilthe heatlevel 1and 5
setting lightsappear toslightly
increasethefeedrateontheminimumheatlevel.
Depressand releasethe AUGERTRIM button untilthe heatlevel 1and 4settinglights appearto slightly
reducethe pelletfeed rateon theminimum heat levelsetting.Usethissetting toreducethe
heat level
outputonlow.
DepressandreleasetheAUGERTRIMbuttonuntilonlytheheatlevel1settinglightison,thisisthefactory
settingandworksformosttypesoffuel.
Open Door:Duringnormaloperationtheheaterwillautomaticallyshutoffiftheviewingdooris openedfor
morethan30seconds.Thisactioncausestheheatertogointovacuumerrormode.Toclearthiserrorandrestart
theheater,closethedoor,depresstheON/OFFbuttonandthenfollowdirectionsfor
restartingheater.
RefillingtheFuelHopper:Formaximumperformancedonotletthepelletfuelhopperdropbelow1/4full.
FuelHopper Lid SafetySwitch:WhentheFuelHopperLidisopenedthe augerwillstopturningtoprevent
accidentalinjury.
KEEPPELLETFUELHOPPERLIDCLOSEDATALLTIMESEXCEPTWHENREFILLING.DONOTOVERFILLHOPPER.
SafetyFeaturesandwarningcode:
1. Yourheaterisequippedwithatemperature“high‐limit”switch,designedtoshutdowntheaugerincaseof
anovertemperaturesituation.Thehigh‐limitswitchisathermosnapdisctypeandmustbemanuallyreset
intheeventofanoverheatshutdown.Oncetheheaterhascooleddown,
youcanreactivatethehigh‐limit
switchbydepressingthemanualresetbuttonlocatedonthehigh‐limitswitch.
2. WhentheHigh‐Limitswitchopens,whichindi catesanoverheatfailure,theHEATLEVELLED’s3&4willflash
red.
3. Yourheater isequippedwithavacuumswitch
thatautomatical lyshutsdowntheauger intheeventofa
exhaustfanmalfunction.
4. WhenaVacuumErrorissensed,theHEATLEVELLED’s1&2willflashred.Checktoensure theglassdooris
latchedproperly.
5. WhentheLow‐Limitswitchopens,(firewentout)the
HEATLEVELLED’s4&5willflashred.Firstcheckfuel
supply,thenchecktoensureAugerisnotjammedandfinallythatpellethopperdoorisproperlyclosed.
6. WhenthePelletsintheBurnPotfailtoigniteHEATLEVELLED’s1&5willflashred.
NOTE:Intheeventthatthehigh‐limitswitchorvacuumswitchactivates,pleasecontactyourdealertodiscuss
thecauseofthisactivationandtoensurethatyourheatercontinuestooperateinasafemanner.Eitherswitch
trippingcanindicateaproblemwiththeoperationofyourheater.