Trane TCONT802AS32DA Dehumidifier User Manual


 
TCONT802AS32DA TOUCH SCREEN AND TCONT803AS32DA TOUCH SCREEN WITH DEHUMIDIFICATION
Pub. No. 18-HD25D19-3
69-1790—3 16
Temperature
Control in
Heat
0680 2 Standard temperature
control in heating.
1, 3 1—less aggressive
temperature control (could
cause temperature
undershoot)
3—more aggressive
temperature control (could
cause temperature overshoot)
Applies to recovery
ramp and use of
auxiliary heat during
recovery.
Choose 1 if getting
temperature
overshoot.
Choose 3 if getting
temperature
undershoot.
Temperature
Control in
Cool
0690 2 Standard temperature
control in cooling.
1, 3 1—less aggressive
temperature control (could
cause temperature
undershoot)
3—more aggressive
temperature control (could
cause temperature overshoot)
Applies to recovery
ramp.
Choose 1 if getting
temperature
overshoot.
Choose 3 if getting
temperature
undershoot.
Temperature
Display Offset
0700 0 No difference in
displayed temperature
and actual room
temperature.
-3, -2,
-1, 0, 1,
2, 3
-3°F (-1.5°C)
-2°F (-1°C)
-1°F (-0.5°C)
0°F (0°C)
1°F (0.5°C)
2°F (1°C)
3°F (1.5°C)
Reset Comfort
Control
0710 0 No comfort control
reset.
1 Resets all Installer Setup
Options to default values and
resets schedule to default
setting.
Only calendar
settings and time are
retained.
Table 4. Installer Setup Menu. (Continued)
Select
Installer
Setup
Number
Factory Setting Other Choices
CommentsOption Description Options Description