Trane TCONT802AS32DA Dehumidifier User Manual


 
TCONT802AS32DA TOUCH SCREEN AND TCONT803AS32DA TOUCH SCREEN WITH DEHUMIDIFICATION
Pub. No. 18-HD25D19-3
13 69-1790—3
Cycles per
hour (cph) for
1st Stage
Heat
0240 5 Heat Stage 1 cycles
per hour (cph)
1-12 1-12 available; typical settings:
1—1 cph used for steam or
gravity system.
3—3 cph used for 2-stage
fossil fuel forced air systems or
hot water systems.
5—5 cph used for single-stage
fossil fuel forced air systems.
9—9 cph used for electric
forced air heat systems
(electric auxiliary heat for heat
pump systems).
Not shown if system
selection is heat
pump. Selection in
this stage changes
default cph for 2nd
stage heat.
Cycles per
hour (cph) for
2nd Stage
Heat
0250 5 Cycles per hour (cph)
for 2nd Stage Heat or
Auxiliary Heat for
2 H/1C Heat Pump
Systems
1-12 1-12 available; typical settings:
1—1 cph used for steam or
gravity system.
3—3 cph used for 2-stage
fossil fuel forced air systems or
hot water systems.
5—5 cph used for single-stage
fossil fuel forced air systems.
9—9 cph used for electric
forced air heat systems
(electric auxiliary heat for heat
pump systems).
Only shown if two
stages of heat are
selected.
Cycles per
hour (cph) for
3rd Stage
Heat
0260 9 Cycles per hour (cph)
for Auxiliary Heat in
3H/2C Heat Pump
Systems
1-12 1-12 available; typical settings:
1—1cph used for steam or
gravity system.
3—3 cph used for 2-stage
fossil fuel forced air systems or
hot water systems.
5—5 cph used for single-stage
fossil fuel forced air systems.
9—9 cph used for electric
forced air heat systems
(electric auxiliary heat for heat
pump systems).
Only shown if 3H/2C
heat pump system is
selected.
Cycles per
hour (cph) for
Em Heat
0270 9 Cycles per hour (cph)
for Emergency Heat
1-12 1-12 is available; typical
settings:
3—3 cph used for 2-stage
fossil fuel forced air systems or
hot water systems.
5—5 cph used for single-stage
fossil fuel forced air systems.
9—9 cph used for electric
forced air heat systems
(electric auxiliary heat for heat
pump systems).
Only shown if 2 heat/
1 cool or 3 heat/2
cool heat pump is
selected.
Continuous
Backlight
0280 0 Backlight not on
continuously. Comfort
control backlight
comes on with each
key press.
1 Backlight is on continuously
(comfort control must have a
common wire attached for this
function).
Option is always
shown; however,
continuously on
backlight works only if
comfort control is
wired with 24 Vac
Common.
Changeover 0300 0 Manual changeover 1 1—auto changeover
Table 4. Installer Setup Menu. (Continued)
Select
Installer
Setup
Number
Factory Setting Other Choices
CommentsOption Description Options Description