Trane PKGP-PRC003-EN Heat Pump User Manual


 
16
PKGP-PRC003-EN
General
Data (7½, 10 Ton)
Table GD-3 — General Data
7½ Ton Convertible Units 10 Ton Convertible Units
WSC090A3, A4, AW WSC120A3, A4, AW
Cooling Performance
1
Gross Cooling Capacity 93,000 121,000
EER
2
10.1 10.1
Nominal CFM / ARI Rated CFM 3,000/2,625 4,000/3,200
ARI Net Cooling Capacity 88,000 113,000
Integrated Part Load Value 10.7
System Power (KW) 8.71 11.19
Heating Performance
1
High Temp. Btuh Rating 88,000 108,000
System Power KW/COP 8.06/ 3.2 9.59/3.3
Low Temp. Btuh Rating 50,000 59,000
System Power KW/COP 6.66/2.2 7.86/2.2
HSPF (Btu/Watts-hr)
Compressor
No./Type 1/Scroll 2/Scrolls
Outdoor Sound Rating (dB)
3
90 88
Outdoor Coil — Type Lanced Lanced
Tube Size (in.) OD .3125 .3125
Face Area (sq ft) 17.00 19.83
Rows/FPI 3/17 3/17
Refrigerant Control Expansion Valve Expansion Valve
Indoor Coil — Type Lanced Lanced
Tube Size (in.) .3125 .3125
Face Area (sq ft) 9.89 12.36
Rows/FPI 4/16 4/16
Refrigerant Control Short Orifice Short Orifice
Drain Connection No./Size (in.) 1/¾ NPT 1/¾ NPT
Outdoor Fan — Type Propeller Propeller
No. Used/Diameter (in.) 1/26 1/26
Drive Type/No. Speeds Direct/1 Direct/1
CFM 6,400 6,700
No. Motors/HP 1/.70 1/.75
Motor RPM 1,075 1,075
Belt Drive Indoor Fan — Type FC Centrifugal FC Centrifugal
No. Used 1 1
Diameter x Width (in.) 12 x 12 15 x 15
Drive Type/No. Speeds Belt/Variable Speed Belt/Variable Speed
No. Motors 1 1
Motor HP (Standard/Oversized) 1.00/3.00 2.00/ 5.00
Motor RPM (Standard/Oversized) 1,750/1,750 1,750/3,450
Motor Frame Size (Standard/Oversized) 56/56 56/56
Filters — Type Furnished
5
Throwaway Throwaway
(No.) Size Recommended (in.) (4) 16 x 25 x 2 (4) 20 x 25 x 2
Refrigerant Charge (Lbs of R-22)
4
12.2 7.9 Circuit #1/7.9 Circuit #2
Notes:
1. Cooling Performance and Heating Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb . Gross capacity does not include the effect of fan motor heat. ARI capacity is
net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification
program, which is based on ARI Standard 210/240.
2. SEER is rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For more information refer to Table PD-25.
4. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
5. Optional 2 inch pleated filters are also available.