3.1.6 Onboard Switch Setting Procedure
1. Detach the front panel.
2. Remove the drain guide, ground line, sensor TCJ, sensor TC, and motor leads.
3. Remove the screws to detach the electric parts box.
Sensor TCJ insertion position
(Insert the sensor drawn from above electric parts.)
Sensor TC insertion position
(Insert the sensor drawn from under electric parts.)
Fan motor connector insertion position
Louver motor connector insertion position
Electric parts box screw
4. Detach the electric parts cover, and set SW01 bit 1 to ON.
Do not touch bit 2 as it is for other setting.
5. Install the removed parts by reversing steps 1 to 4.
(Insert the sensors and motor leads firmly into their correct positions.)