Toshiba RAV-SM560XT-E Air Conditioner User Manual


 
– 35 –
140
633
320
160
742
1093
60
9-5-5. Console Installation
Select the terminal of Selector-SW from [C position]
to [F position].
Fig. 9-5-18
390 mm
or more
375 mm
or more
CAUTION
Failure to firmly install the unit may result in personal
injury and property damage if the unit falls.
In case of block, brick, concrete or similar type walls,
make 5 mm dia. holes in the wall.
Insert clip anchors for appropriate Mounting screws
4.
NOTE :
Secure four corners and lower parts of the
Installation plate 1 with 6 to 8 mounting screws to
install it.
<Condition for installation>
The unit must not decline more than 15 mm in either
axis.
Fig. 9-5-22
Projection
15 mm or less
44
44
4 Mounting screw
4 x 25
ss
ss
s
Clip anchor
(local parts)
5 mm dia. hole
Anchor bolt
15 mm
Indoor unit
Hook
11
11
1 Installation
plate
44
44
4 Mounting screw
44
44
4 Mounting screw
<Install the indoor unit>
Install the Installation plate 1 at the wall according
to the Paper pattern.
Hang the indoor unit on the hooks of the Installation
plate 1.
Fix the lower portion of the indoor unit with Mounting
screws 4 (2 places).
Fig. 9-5-21
<Cutting a hole and mounting the Installation plate>
When installing the rear piping, determine the pipe
hole position, drill the pipe hole (80 mm) at a slight
downward slant to the outdoor side.
For mounting of the Installation plate 1, use the
Paper pattern, which is inside the package box cover.
Fig. 9-5-19
Fig. 9-5-20
Rear piping hole 80
Floor
REMOCON
INSTALL
A
C
B
F
<Piping and Drain Hose Installation>
The piping direction can
be the following 3 ways
with the Drain hose.
Each piping direction
should be connected with
the Flexible pipe 5.
Cut or remove the
determined direction
slit or cover.
Slit for upper
piping
Cover for
side piping
Side piping
Rear piping
Bottom piping
Cover for rear
upper piping
Fig. 9-5-22
Fig. 9-5-23