5. SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Indoor Unit
RAV-SM1403DT-A, RAV-SM1603DT-A
No.
1
2
3
4
Parts name
Fan motor
TA sensor
TC sensor
TCJ sensor
Type
SWF-240-600-4A
Lead wire length : 1200mm
Ø6 size lead wire length : 1200mm Vinyl tube (Black)
Ø6 size lead wire length : 1200mm Vinyl tube (Red)
Specifications
Output (Rated) 600 W
10 k at 25°C
10 k at 25°C
10 k at 25°C
5-2. Outdoor Unit
RAV-SM1603AT-E, RAV-SM1603ATZ-E, RAV-SM1603ATZG-E
No.
1
2
3
4
5
6
7
8
9
10
11
12
Parts name
Fan motor
Compressor
Reactor
Outdoor temp. sensor (To-sensor)
Heat exchanger sensor (Te-sensor)
Suction temp. sensor (Ts-sensor)
Discharge temp. sensor (Td-sensor)
Fuse (Switching power (Protect))
Fuse (Inverter, input (Current protect))
4-way valve solenoid coil
Compressor thermo. (Protection)
Coil (Pulse Motor Valve)
Type
ICF-280-100-1R
DA422A3F-25M
CH-65
STF-01AJ502EJ
US-622
UKV-25D100
Specifications
Output (Rated) 100 W
3 phase, 4P, 3500 W
2.75 – 3.15 mH, 27.8 ± 1.9 V
10 k at 25°C
10 k at 25°C
10 k at 25°C
50 k at 25°C
T3.15 A, AC 250 V
50 A, AC 250 V
AC 220 – 240 V
OFF : 125 ± 4°C, ON : 90 ± 5°C