Toshiba RAV-SM1403DT-A Air Conditioner User Manual


 
– 15 –
1-1-4. Under Ceiling Type
<Twin type>
Indoor unit 1 RAV- SM802CT-E
Model Indoor unit 2 RAV- SM802CT-E
Outdoor unit RAV- SM1603AT(Z)(ZG)-E
Cooling capacity (kW) 14.0
Heating capacity (kW) 16.0
Indoor unit
Power supply 1 phase 230V (220 – 240V) 50Hz
Running current (A) 23.88 – 21.89
Power consumption (kW) 4.99
Cooling Power factor (%) 95
EER 2.81
Electrical
Energy efficiency class
characteristics
Running current (A) 22.44 – 20.57
Power consumption (kW) 4.69
Heating Power factor (%) 95
COP 3.41
Energy efficiency class
Fan Centrifugal fan
Fan unit Standard air flow H/M/L (m³/min.) 18.5 / 16.7 / 14.6
Motor (W) 60
Sound pressure level H/M/L (dB•A) 38 / 36 / 33
Sound power level H/M/L (dB•A) 53 / 51 / 48
Outdoor unit
Power supply 1 phase 230V (220 – 240V) 50Hz
Standard length (m) 7.5
Refrigerant
Min. length (m) 5
Max. total length (m) 50
pipe
Height
Outdoor lower (m) 30
difference
Outdoor higher (m) 30
Fan Propeller fan
Fan unit Standard air flow volume (m³/min.) 103
Motor (W) 100 + 100
Gas side
Main (mm) 15.9
Connecting
Sub (mm) 15.9
pipe
Liquid side
Main (mm) 9.5
Sub (mm) 9.5
Sound pressure level Cooling/Heating (dB•A) 51 / 53
Sound power level Cooling/Heating (dB•A) 68 / 70
: IEC standard