Toshiba RAV-SM1403AT-E1 Air Conditioner User Manual


 
– 89 –
Discharge
port cabinet
Bell mouth
Remove
two screws
Discharge
port cabinet
Bell mouth
Minus screwdriver
Fan guard
Hooking claw
Discharge port cabinet
Slit (3 positions)
Claw (3 positions)
Bell mouth
Part name
Fan guard
Procedure
1. Detachment
1) Perform works of items 1 of c and d.
2) Remove the discharge port cabinet, and
put it down so that the fan guard side
directs downward.
Perform work on a corrugated card-
board, cloth, etc. to prevent flaw to the
product.
3) Remove screws fixing the bell mouth.
(M4 x 8, 2 pcs.)
4) Remove the bell mouth.
5) Remove the hooking claws by pushing
with minus screwdriver along with the
arrow mark as shown in right figure.
2. Attachment
1) Insert claw of the fan guard in hole of
discharge port cabinet. Push the hooking
claws (5 positions) with hands and fix the
claws.
After all the attachment works are
completed, check that all the hooking
claws are fixed to the specified posi-
tions.
2) Mount the bell mouth by hooking three
claws at upper side of the bell mouth in
the slits on the discharge port cabinet.
3) After attachment, fix the bell mouth with
screws. (M4 x 8, 2 pcs.)
No.
l
Remarks