Toshiba RAV-SM1104UT-E Air Conditioner User Manual


 
– 64 –
Ta
(˚C)
F4F5
F5
47
42
No.
6
Item
Air speed
selection
(Continued):
In case of 4-way
Discharge
Cassette type
Outline of specifications
3) In heating operation, the mode changes to [UL] if thermostat
is turned off.
4) If Ta 25°C when heating operation has started and when
defrost operation has been cleared, the air conditioner
operates with (H) mode or higher mode for 1 minute after Tc
entered in E zone of cool air discharge preventive control
(Item 7).
5) In automatic cooling/heating operation, the revolution
frequency of (HH) is set larger than that in the standard
cooling/heating operation.
However the revolution
frequency is restricted in the
automatic heating operation as
shown in the following figure.
6) Self-clean operation
When performing self-clean operation after stopping the
cooling operation, the mode becomes [UL] (210 rpm).
Tap
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
SM56 SM80 SM110 SM140 SM160
Revolution speed (rpm)
610 630 700 700 700
550 590 670 670 670
500 530 660 660 660
450 470 640 650 650
400 450 620 640 640
390 440 610 630 630
370 410 550 560 580
350 380 490 490 530
340 370 480 480 520
330 350 450 460 490
320 330 400 430 450
310 320 400 420 440
250 250 300 300 300
Item code
[5d]
SW501 (1)/(2)
Tap
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
Standard Type 1 Type 3 Type 6
0136
OFF/OFF ON/OFF OFF/ON ON/ON
HEAT COOL HEAT COOL HEAT COOL HEAT COOL
HH HH HH HH
HH HH
H+ H+, H H+, H
H+, H H+, H
L+, L L+, L
H+
HH H
HH H L+ L+
H+ H+ L L
HL+
HL+L
L+ L
L+ L
L
UL UL UL UL
Remarks
Selection of high
ceiling type
Item code:
[5d] or selection of
high ceiling on P.C.
board SW501
However only when
the high ceiling
selection is set to
[Standard]
[Self-clean
] is
displayed.
Revised 2: Jun., 2008