– 9 –
Parts name
Fan motor (for indoor)
Thermo sensor
(TA-sensor)
DC-DC transformer (T01)
Microcomputer
Power relay (RY01), Com-
mon relay (RY02)
Heat exchanger sensor
(TC-sensor)
Line filter (L01)
Diode (DB01)
Capacitor (C02)
Fuse (F01)
Power supply IC (IC01)
Varistor (R21, R109)
Resistor (R01)
Louver motor
Specifications
DC 35V, 19W
10kΩ at 25°C
DC390V, Secondary DC35V, 12V, 7V
Coil : DC12V 75mA, Rated AC250V 20A
10kΩ at 25°C
10mH, AC 0.6A
4A, 600V
100µF, 450V
T3.15A, 250V
4A, 600V
560V
5.6 Ω, 5W
Output (Rated) 2W, 10poles, 1phase DC 12V
4. SPECIFICATIONS OF ELECTRICAL PARTS
4-1. Indoor Unit
RAS-10SK-E
RAS-10SKX
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Type
ICF-35-19-3
or
TICF-35-19-3
(microprocessor)
SWT-34
TMP87CK40F
DI1U
(microprocessor)
RF-103YOR6
RBV-406
CEAUF2W101M20
MT3
MA2830-FJ
15G561K
ERF-5TK5R6
MP35EA7
Specifications
Output (Rated) 750W, 2pole, 1phase, 220/230/240V, 50Hz
Winding resistance (Ω)
(at 20°C)
Output (Rated) 18W, 6pole, 1phase, 220/230/240V, 50Hz
Winding resistance (Ω)
(at 20°C)
500V AC, 1.5µF
400V AC, 25µF
U/T 6.1A (80°C), OPEN 135±5°C, CLOSE 78±11°C
No.
1
2
3
4
5
Type
PH102T1-4C
UE6-21SJ5P
SK-50FMP
SK-40CMP25U1
J-MRA99285-9201
Parts name
Compressor
Fan motor (for outdoor)
Running capacitor
(for fan motor)
Running capacitor
(for compressor)
Overload relay
Red-Black
3.88
White-Black
5.06
White-Black
370
Red-Black
370
4-2. Outdoor Unit
RAS-10SA-E
RAS-10SAX