– 51 –
Procedure
1) Stop the operation of air-conditioner, and disconnect
the power cord from the AC supply.
2) Remove E-parts cover.
(1- ST1T ø4 x 10 )
3) Remove the cord clamp (2- ST2T ø4 x 12 ) and
remove the connecting cable.
4) Remove the front cabinet. (7- ST1T ø4 x 10 with
nylon washer)
• Pull the front lower portion toward you, and remove
it pulling out upward.
1) Remove the fixing screw securing the capacitor
band.
(1- ST2T ø4 x 8 )
2) Remove the cable connected to the terminal.
1) Remove the fixing screw.
(1- ST2T ø4 x 8 )
2) Remove the cable connected to the terminal.
1) Perform the process above.
2) Remove terminal cover of compressor.
3) Remove OL holder and pull OL relay up.
4) Remove Fustons of leads.
No.
Part name
Common
procedure
Capacitor for
compressor
Capacitor for fan
motor
Overload relay
Remarks
Refer to [Electrical parts list and
location] in page 55.
Same as above.
10-3. Outdoor Unit (RAS-10SA-E, RAS-10SAX)