Toshiba RAS-10SKX Air Conditioner User Manual


 
– 25 –
<How to connect the connecting cable>
Wiring of the connecting cable can be carried out
without removing of the front panel.
(1) Remove the front panel.
Fully open the front panel. Disengage the support
arm located in the upper center while pushing its
handle leftwards, and then remove the front panel
toward you.
(2) Remove the terminal cover and cord clamp.
(3) Insert the connecting cable (according to local
codes) into pipe hole on the wall.
(4) Take out the connecting cable through the cable
slot on the rear panel so that it is exploded by
about 15 cm long in the front side.
(5) Insert the connecting cable fully into the terminal
block and secure it by screw tightly.
(6) Tightening torque:1.2 N•m (0.12 kgf•m)
(7) Secure the connecting cable with the cord clamp.
(8) Fix the terminal cover and front panel on the indoor
unit.
CAUTION
Be sure to refer the wiring system diagram
labeled inside the front panel.
Check local electrical codes and also any
specific wiring instructions or limitation.
<Stripping length of connecting cable>
For a three conductor cable
NOTE :
Use stranded wire only.
Wire type:More than H05 RN-F
Fig. 8-4-10
<How to install the front cabinet on the indoor
unit>
Install the front cabinet through the opposite order of
"How to remove the front cabinet".
When the panel is removed and mounted again, take
the following actions:
After fastening the two screws, one each at the left
and right of the air outlet, be sure to push the upper
center
1
right end
2
, left end
3
and the lower
center
4
of the air outlet, and confirm that no gap is
left between the front cabinet and the rear plate.
If cooling (dry) operation is made without
pushing the air outlet, dew can be deposited
on the front cabinet surface. In addition a gap
between the front cabinet and the rear plate
will become wider, spoiling the appearance.
3
1
2
4
Push Push
Push
Push
Fig. 8-4-11
Fig. 8-4-9
10mm
40mm
50mm
10mm
Earth line
1
2
Connecting
cable
about 15cm
Terminal block
Cord
clamp
Screw
Screw
Connecting cable
Earth
line
Terminal
cover
Screw
21