– 53 –
FILE NO. SVM-07008
10-2-4. Wiring connection
<How to connect the connecting cable>
Wiring of the connecting cable can be carried out
without removing of the front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward
you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local
cords) into the pipe hole on the wall.
4. Take out the connecting cable through the cable
slot on the rear panel so that it protrudes about
15 cm from the front.
5. Insert the connecting cable fully into the terminal
block and secure it tightly with screws.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air
inlet grille on the indoor unit.
CAUTION
• Be sure to refer to the wiring system diagram
labeled inside the front panel.
• Check local electrical cords and also any specific
wiring instructions or limitations.
10-2-5. Piping and drain hose installation
<Piping and Drain Hose Forming>
* Since dewing results in a machine trouble, make
sure to insulate both the connecting pipes. (Use
polyethylene foam as insulating material.)
Fig. 10-2-8
1. Die-cutting Front panel slit
Cut out the slit on the left or right side of the front panel
for the left or right connection and the slit on the
bottom left or right side of the front panel for the
bottom left or right connection with a pair of nippers.
2. Changing drain hose
For left connection, bottom-leftward connection and
rear-leftward connection’s piping, it is necessary to
change the drain hose and drain cap.
<How to remove the Drains Cap>
Clip drain cap by needle-nose pliers, and pull out.
Fig. 10-2-9
<How to install the Drain Hose>
Firmly insert drain hose connecting part until hitting on
a heat insulator.
Fig. 10-2-10
Rear right
Rear left
Die-cutting
Front panel slit
Changing
drain hose
Piping preparation
Bottom left
Left
Bottom right
Right
Heat insulator
Drain hose
.
1
2
3
1
3
2
NOTE :
• Use stranded wire only.
• Wire type : H07RN-F or more
<How to install the air inlet grille on the indoor unit>
• When attaching the air inlet grille, the contrary of the removed
operation is performed.
Earth line
Connecting cable
about 15 cm
Stripping length of the connecting cable
Connecting cable
Screw
Screw
Earth line
Terminal block
Screw
Cord clamp
Terminal cover
10 mm
50 mm
10 mm
110 mm