2. SPECIFICATIONS
2-1. Specifications
Unit model Indoor RAS-10SKV-E, RAS-10SKV-A
Outdoor RAS-10SAV-E, RAS-10SAV-A
Cooling capacity (kW) 2.5
Cooling capacity range (kW) 1.1 - 3.0
Heating capacity (kW) 3.2
Heating capacity range (kW) 0.9 - 4.1
Power supply 1Ph/50Hz/220-240V
Electric Indoor Operation mode Cooling Heating
characteristic Running current (A) 0.16 - 0.14 0.16 - 0.14
Power consumption (W) 30 30
Power factor (%) 87 87
Outdoor Operation mode Cooling Heating
Running current (A) 3.44 - 3.16 3.96- 3.63
Power consumption (W) 720 830
Power factor (%) 95 95
Starting current (A) 4.12 - 3.77
COP (Cooling / Heating) 3.33 3.72 3.33/3.72
Operating Indoor High (Cooling / Heating) (dB-A) 38/40
noise Medium (Cooling / Heating) (dB-A) 33/35
Low (Cooling / Heating) (dB-A) 29/30
Outdoor (Cooling / Heating) (dB-A) 48/50
Indoor unit Unit model RAS-10SKV-E, RAS-10SKV-A
Dimension Height (mm) 250
Width (mm) 740
Depth (mm) 195
Net weight (kg) 8
Fan motor output (W) 20
Air flow rate (Cooling / Heating)
(m
3
/ min)
8.7/9.6
Outdoor unit Unit model RAS-10SAV-E, RAS-10SAV-A
Dimension Height (mm) 530
Width (mm) 660
Depth (mm) 240
Net weight (kg) 29
Compressor Motor output (W) 750
Type Single rotary type with DC-inverter variable speed control
Model DA89X1C-23FZ
Fan motor output (W) 20
Air flow rate (Cooling / Heating)
(m
3
/ min)
27/27
Piping Type Flare connection
connection Indoor unit Liquid side (mm)
∅6.35
Gas side (mm)
∅9.52
Outdoor unit Liquid side (mm)
∅6.35
Gas side (mm)
∅9.52
Maximum length (m) 10
Maximun charge-less length (m) 10
Maximum height difference (m) 8
Refrigerant Name of refrigerant R410A
Weight (kg) 0.63
Wiring Power supply 3 Wires: Includes earth (Outdoor)
connection Interconnection 4 Wires: Includes earth
Usable temperature range Indoor (Cooling / Heating)
(
o
C)
21 - 32/Up to 27
Outdoor (Cooling / Heating)
(
o
C)
15 - 43/-10 - 24
Accessory Indoor unit Installation plate 1
Wireless remote controller 1
batteries 2
Remote controller holder 1
Super Oxi Deo filter 1
Super Sterilizer filter 1
M
ounting screw 6 (∅4 x 25L)
Plasma air purifier -
Installation manual 1
Owner's manual 1
Outdoor unit Drain nipple 1
Water proof rubber cap -
* The specification may be subject to change without notice for purpose of improvement.
FILE NO. SVM-07008