Horizontal
blowing
Inclined
blowing
Blowing
downward
Air direction
Inclined
blowing
Horizontal
blowing
Initial setting of "Cooling storage position"
Louver : Directs downward (48°)
Heating operation/
AUTO (HEAT)
Initial setting of “Heating storage position”
Louver : Directs downward (115.7˚)
Item
7. Louver control
1) Louver
position
Operation flow and applicable data, etc.
This function controls the air direction of the indoor unit.
Description
• Swing operation is performed in width 35° with the stop position as
the center.
• If the stop position exceeds either upper or lower limit position,
swing operation is performed in width 35° from the limit which the
stop position exceeded.
3) Swing
2) Louver position in heating operation
2) Air direction adjustment
• The position is automatically controlled according to the operation
• The set louver position is stored in memory by the microcomputer,
The angle of the louver is indicated as the louver closes fully is 0°.
1) Louver position in cooling operation
mode (COOL/HEAT).
and the louver returns to the stored position when the next operation
is performed. (Cooling/Heating memory position)
• Swing
When pressing
[SWING] button during
operation, the louver
starts swinging.
• The louver position can
be arbitrarily set up by
pressing [FIX] button.
– 33 –
FILE NO. SVM-07008