Toshiba MMK-AP0122H Air Conditioner User Manual


 
24
New check code
1. Difference between the new check code and the current system
The displaying method of the check code changes in this model and after.
<Display on wired remote controller>
[ ] goes on.
[UNIT No.] + Check code + Operation lamp (Green) flash
<Display on sensor part of wireless>
Block display of combination of [ ] [ ] [ ]
<Display on indicater on wireless remote controller
receiver part>
Unit No. and check code are displayed.
In a case of error with auxiliary code, check code and
auxiliary code are displayed alternately.
→
Used characters
Characteristics of code classification
Block display
Check code in current system
Hexadecimal notation, 2 digits
Few classification of communication/incorrect setup system
Indoor P.C. board, Outdoor P.C. board, Cycle, Communication
New check code
Alphabet + Decimal notation, 2 digits
Many classification of communication/incorrect setup system
Communication/Incorrect setup (4 ways), Indoor protection,
Outdoor protection, Sensor, Compressor protection, etc.
Display
A
C
E
F
H
J
L
P
Classification
Unused
Central control system error
Communication system error
Each sensor error (Failure)
Compressor protective system error
Unused
Setup error, Other errors
Protective device operation