Superior CF6500-CMP Indoor Fireplace User Manual


 
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
13
Cleaning and Servicing
WARNING: TURN OFF THE APPLIANCE
AND ALLOW TO COOL BEFORE CLEAN-
ING.
WARNING: ALWAYS TURN OFF THE GAS
SUPPLY TO THE PILOT BEFORE CLEAN-
ING. BEFORE RE-LIGHTING, REFER TO
THE LIGHTING INSTRUCTIONS IN THIS
MANUAL. INSTRUCTIONS ARE ALSO
FOUND ON THE PULL-OUT PANEL LO-
CATED IN THE APPLIANCE LOWER CON-
TROL COMPARTMENT. ONLY LIMITED
CLEANING WILL BE REQUIRED UNDER
THE NORMAL USE OF THE APPLIANCE.
THE EXTERNAL CASE SHOULD BE OCCA-
SIONALLY DUSTED AND WIPED WITH A
DAMP SOAPY CLOTH.
Clean the glass only when necessary. Wipe
surface with a clean, dampened, soft cloth.
Follow with a dry, soft towel as desired. Take
care not to scratch the glass surface.
WARNING: DO NOT USE ABRASIVE
CLEANERS. NEVER CLEAN THE GLASS
WHEN IT IS HOT.
If, after a period of use, the flames start to
exhibit unusual shapes and behavior, or the
burners fail to ignite smoothly, then the burner
holes may require some cleaning. If this oc-
curs, it is preferable to contact your nearest
dealer to service the appliance.
Intentional misuse or deliberately fragmenting
the material could be hazardous to health by
inhaling.
These CF appliances are intended for use as a
gas heater as described in these instructions
and should not be used for any other purpose.
Repair and work involving replacing parts
should only be carried out by a qualified ser-
vice person.
Always shut off the gas supply and allow the
appliance to cool before beginning any service
work.
Always check for gas leaks after servicing.
If any major repair or service is required, the
qualified service person must contact the SFC,
INC. service department before proceeding.
REPLACEMENT PARTS
Exploded views of the appliances with num-
bered parts and parts lists can be found on
pages 18 and 19. All parts should be ordered
through your SFC distributor or dealer. Parts
will be shipped at prevailing prices at time of
order. When ordering repair parts, always
give the following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any
questions concerning the installation of this
system, please contact your distributor. For the
name of your nearest distributor contact:
SFC
1110 West Taft Avenue
Orange, CA 92865
Alternatively, at least annually, the glass enclo-
sure panel should be removed and the inside of
the firebox and the control compartments
cleaned using a vacuum cleaner to remove
dust. Remove the top and bottom logs, gently
handling by holding each log at each end and
set on a piece of paper or cloth to avoid getting
any debris on carpet or floor. Use the vacuum
cleaner to remove the embers from the base
and walls of the firebox and from around the
burners. More frequent cleaning may be re-
quired due to excessive lint from carpeting
material, etc. It is important that control com-
partments, burners and circulating air pas-
sageways of the heater be kept clean. Replace
the logs as detailed in Step 9 Log Assembly.
Place Rockwool on screen of front burner.
CAUTION: REPLACE THE GLASS ENCLOSURE
PANEL BEFORE USING THE APPLIANCE (RE-
FER TO STEP 11).
IMPORTANT SAFEGUARDS
Even though your CF appliance gives a very
realistic appearance of a wood-burning fire, it
must not be used for burning wood or other
similar materials. To avoid damage to the appli-
ance or possible personal injury, matches, pa-
per, garbage or any other material must not be
placed or thrown on top of the logs or into the
flames. Always ensure that the appliance glass
enclosure panel is firmly fixed in place. Do not
remove the glass enclosure panel during nor-
mal operation of the appliance.
To avoid personal injury, do not touch hot
surfaces when the appliance is operating. Close
supervision of children is necessary when the
appliance is in use.
SPECIAL WARNINGS
Do not open the louvered control compartment
access panel from the middle when unit is hot.
Only the ends of the louvers are cool to the
touch.
The glowing logs are manufactured from bonded
ceramic fiber which is commonly used material
in the heating industry worldwide.
Maintenance
CAUTION: DO NOT OPERATE THE APPLIANCE
WITH A BROKEN, DAMAGED OR MISSING
CATALYTIC COMPONENT.
The appliance should be inspected before use
and at least annually by a professional service
person. Replace the catalytic component if CO
levels measured at the appliance vent outlet
exceed 1/1000 of 1% after (10 Min) of burn-
ing. Replacement of the catalytic component
should only be completed by a qualified ser-
vice person at least every 20 years.
Ensure the air shutter openings are not ob-
structed (
see Figure 22
).