Sterling STT70 Dehumidifier User Manual


 
STT40 / STT70
Technical data 10-5
10. Technical data
10.1. STT40
amount of dehumidified air: max. 1,412.69 ft
3
/h, (40 m
3
/h)
operating voltage: 230 V/AC/50 Hz
special voltages can be supplied upon request
connected load:2.6 kW
calorific output (drying)
*
:max. 1.5 kW
*depending on the equipment with hopper heaters
calorific output (regenerating): 0.7 kW
driving power (drying, regenerating): 0.37 kW
drying temperature: max. 356°F (+180 °C)
width: 11.8 in. (300 mm)
depth: 27.5 in. (700 mm)
height: 35.5 in. (900 mm)
weight: approx. 149.9 lbs (68 kg)
noise: approx. 61 dB (A)
options:timer clock
dew point display
return air cooler
Return Air Cooler (optional)
water flow rate in the water main network*: approx. 7.16 ft
3
/h (0.2 m
3
/h)
(
*
water temperature: 42.8°F) (+6 °C)
Ø pipe connection: 0.5 in. (12 mm)
10.2. STT70
amount of dehumidified air: max. 2,472.03 ft.
3
/h (70 m
3
/h)
operating voltage: 400 V/3 AC/50 Hz
special voltages can be supplied upon request
connected load:5.0 kW
calorific output (drying)
*
:max. 3.0 kW
*depending on the equipment with hopper heaters
calorific output (regenerating): 1.2 kW
driving power (drying, regenerating): 0.75 kW
drying temperature: max. 356°F (+180 °C)
width: 15.7 in. (400 mm)
depth: 35.5 in. (900 mm)
height: 35.5 in. (900 mm)
weight: approx. 227.17 lbs. (103 kg)
noise: approx. 66 dB (A)
options:timer clock
dew point display
return air cooler
Return Air Cooler (optional)
water flow rate in the water mains network*: approx. 14.13ft.
3
/h (0.4 m
3
/h)
(
*
water temperature: 42.8°F (+6 °C)
Ø pipe connection: 0.5 in. (12 mm)