Dehumidifying Dryers Chapter 4: Operation 30 of 59
Entering Operating Parameters to Select Modes
To enter the display:
1. Press the
Mode Display key to view the Run/Stop & Alarm 1 Modes.
2. Press
and to set the higher or lower the values of the parameter or turn
that function On or Off.
The SV readout displays the different values for the parameter within a mode.
3. To switch modes within a level, press and hold the Level Display key for one
(1) second.
The PV readout will display the different parameters within each mode.
4. Use short presses on the Mode Display key to display each parameter within
a mode.
The SV readout displays the different values for the parameter within a mode.
5. Press and to set the higher or lower the values of a parameter or turn
that function On or Off.
6. Press Level Key once to return to the Process Temperature Setting.
Figure 6: Settings for Process Temperature Controller (E5CN), Part No. A0555757
Mode Parameter Setting range Default Manuf. setting
Run/Stop Run/Stop Run -
Operation
Alarm value 1 -1999 to 9999 0 25
Mode Parameter Setting range Default Manuf. setting
AT execute/cancel ON, OFF OFF ?
Temperature input shift -199.9 to 999.9 0.0 -
Proportional Band 0.1 to 999.9 8.0 ?
Integral Time 0 to 3999 233 ?
Adjustment
Derivative Time 0 to 3999 40 ?