Sterling SDAA 25-100 Dehumidifier User Manual


 
Dehumidifying Dryers Chapter 4: Operation 27 of 59
Indicator Name Description
ALARM1 ALARM 1 LED
Lights in the Operation Indicator Section when
the output function assigned to auxiliary output
1 turns on. The ALARM1 indicator lights when
the process temperature exceeds the set point
temperature by more than the alarm deviation
value. Alarm output de-energizes the heaters.
Heaters re-energize when the temperature falls
within the acceptable range.
Identifying Temperature Controller Keys
Indicator Name Description
Mode Key Press the Mode key to shift the display to the next
set of parameters. The menu screen displays.
Down Key Press the Down arrow key to lower the process air
set point temperature. During setup, it lets you
decrease the value of the parameter displayed on
the set point LED readout.
Up Key Press the Up arrow key to raise the process air set
point temperature. During setup, it lets you
increase the value of the parameter displayed on
the set point LED readout.
Setting the Process Air Temperature
When setting the process air temperature, consult with the resin manufacture for the
recommended drying temperature.
To change the process air temperature set point with the dryer running:
Press
to raise the set point to the temperature you want.
Press
to lower the set point to the temperature you want.