Large Dehumidifying Dryers Functional Description 25
Electrical Features
CFM
Dryer AMP Draw
600 850 1000 1250 1500 2000 2500 3000
Standard voltage Low Heat (Electric Dryers)
Full load Amps
208v/3/60Hz. 152 217 249 314 378
230v/3/60Hz. 137 196 225 284 342
N/A
400v/3/50Hz. 79 113 129 163 197 270 339 424
460v/3/60Hz. 69 98 112 142 171 234 294 370
575v/3/60Hz. 55 78 90 114 137 188 236 295
Standard voltage High Heat (Electric Dryers)
Full load Amps
208v/3/60Hz. 207 296 342 430
230v/3/60Hz. 187 267 309 389
N/A
400v/3/50Hz. 108 154 178 224 269 366 N/A
460v/3/60Hz. 94 134 154 194 234 318 399 494
575v/3/60Hz. 75 107 123 156 187 254 319 395
Standard voltage (Gas Dryers)
Full load Amps
208v/3/60Hz. 36 47 48 61 75 120 150 191
230v/3/60Hz. 33 43 44 55 67 109 136 173
400v/3/50Hz. 19 25 32 39 62 78 99
460v/3/60Hz. 16 22 28 34 54 67 87
575v/3/60Hz. 13 17 22 27 43 54 69
Electrical Options
9 Denotes availability
CFM
Option Description
600 850 1000 1250 1500 2000 2500 3000
AP1 control
(Includes: 4”x2” touch screen and dew point monitoring, 7
day timer, dirty filter indication, & temperature setback.)
9
Hopper mounting of the process heater box
9 9
Remote operator interface
CF
Redundant process temperature safety 9 (Standard w/High Performance)
Ethernet module for remote communication w/ Data logging
9
CSA approval
9
UL rating
9
Supply voltages 400/3/50 (includes CE compliance)
9
Audible & Visual Alarm 9 (Standard w/High Performance)