Sterling 882.00295.00 Dehumidifier User Manual


 
Large Dehumidifying Dryers Functional Description 25
Electrical Features
CFM
Dryer AMP Draw
600 850 1000 1250 1500 2000 2500 3000
Standard voltage Low Heat (Electric Dryers)
Full load Amps
208v/3/60Hz. 152 217 249 314 378
230v/3/60Hz. 137 196 225 284 342
N/A
400v/3/50Hz. 79 113 129 163 197 270 339 424
460v/3/60Hz. 69 98 112 142 171 234 294 370
575v/3/60Hz. 55 78 90 114 137 188 236 295
Standard voltage High Heat (Electric Dryers)
Full load Amps
208v/3/60Hz. 207 296 342 430
230v/3/60Hz. 187 267 309 389
N/A
400v/3/50Hz. 108 154 178 224 269 366 N/A
460v/3/60Hz. 94 134 154 194 234 318 399 494
575v/3/60Hz. 75 107 123 156 187 254 319 395
Standard voltage (Gas Dryers)
Full load Amps
208v/3/60Hz. 36 47 48 61 75 120 150 191
230v/3/60Hz. 33 43 44 55 67 109 136 173
400v/3/50Hz. 19 25 32 39 62 78 99
460v/3/60Hz. 16 22 28 34 54 67 87
575v/3/60Hz. 13 17 22 27 43 54 69
Electrical Options
9 Denotes availability
CFM
Option Description
600 850 1000 1250 1500 2000 2500 3000
AP1 control
(Includes: 4”x2” touch screen and dew point monitoring, 7
day timer, dirty filter indication, & temperature setback.)
9
Hopper mounting of the process heater box
9 9
Remote operator interface
CF
Redundant process temperature safety 9 (Standard w/High Performance)
Ethernet module for remote communication w/ Data logging
9
CSA approval
9
UL rating
9
Supply voltages 400/3/50 (includes CE compliance)
9
Audible & Visual Alarm 9 (Standard w/High Performance)