SoundCraft RK-65K Home Security System User Manual


 
(ENTER)(THRU)
(THRU)
Radio Key
®
RK-65K Operating Guide
Secura Key 17
Confi gure the Relay (RK65K/RK100M)
The relay is set at the factory to be normally open and to close
upon presentation of a valid transponder or upon activation of
the remote open (Request to Exit) input. It may be changed to
normally closed or to SecuRelay™ operation. A normally open
relay is used for a “fail-secure” electric lock or door strike and
to trigger a gate operator. A normally closed relay is used for
“fail-safe” devices such as magnetic locks. The Secura Key
SecuRelay™ (sold separately) is a remote intelligent relay
used to prevent entry when the access control unit is physically
attacked. (NOTE: When placed in the SecuRelay™ mode the
“Remote Open” input is disabled.) To confi gure the relay, put
the unit in the Program mode (See Page 8). Press THRU two
times. Then press either the “6”, “7” or “8”. Press ENTER.
Selections are:
6. Normally Open (Factory default)
7. Normally Closed
8. SecuRelay™ Option.
For example, to configure the relay normally closed, the
following sequence would be followed:
+ + 7 +