Sears N8MPL100F20B1 Furnace User Manual


 
ManufacturersNumber (Mfr No -See RatingPlate)
ALL Models(N8MPL)
Specifications
N8MPL N8MPL N8MPL N8MPL N8MPL N8MPL N8MPL
O5OB12 O75B12 O75F16 1OOF20 1OOJ22 125J20 125J22
General
Input(Btuh) 50,000 75,000 75,000 100,000 100,000 125,000 125,000
Output(Btuh) 40,000 60,000 60,000 80,000 80,000 100,000 100,000
Temp.Rise(F) 35-65 35-65 25-55 35-65 30-60 30-60 30-60
Electrical(VoltslHz) 115160 115160 115160 115160 115160 115160 115160
RatingPlateAmps. 9.7 9.2 9.7 11.7 13.2 11.7 13.2
OasType .atI LP .atI LP .at .at .at .at .atI LP
Transformer Size (VA) 40
T'stat Heat Anticipator .50
Gas &Ignition
Std.MainOrifices(No/Size) 2I#42 2I#54 3/#42 3/#54 3/#42 3/#54 4/#42 4/#54 4/#42 4/#54 5/#42 5/#54 5I#42 5/#54
GasValveHoneywell VR82055
RegulationType SNAP
ManifoldPress.(Inch'sWC) 3.5 110.0 3.5 110.0I 35 110.0 3.5 110.0 I 35 110.0 35 110.0 3.5 110.0
IgnitionType/Series HotSurface
Combustion
FlueOutletSize(Inches) 4 4 4 4 4 4 4
Limits&Controls
ThermalSensor(F) 300 300 300 300 300 300 300
LimitControl SeePartsList SeePartsList SeePartsList SeeParts List SeePartsList SeePartsList SeePartsList
Std.PressureSw.(PartNo) 1013529 1013529 1013529 1013529 1013529 1013529 1013529
Press(Close) -0.69 -0.69 -0.69 -0.69 -0.69 -0.69 -0.69
Press(Open) -0.59 -0.59 -0.59 -0.59 -0.59 -0.59 -0.59
FurnaceControl(Type) Integrated
FurnaceControl On 30
(Timed-secs) Off 60,100,140,180
BlowerData
Type&Size 11-8 11-8 11-10 11-10 11-10 11-10 11-10
MotorType/H.p. PSC/II2 PSC/I/2 PSC/I/2 PSC/II2 PSC/3/4 PSC/I/2 PSC/314
Cap.MfdNolts 10/370 7.51370 10/370 10/370 40/370 10/370 40/370
FilterType(600 FPM) Washable Washable Washable Washable Washable Washable Washable
FUterSize(") (NotSupplied) 14x25x1 14x25x1 16x25x1 16x25x1 20x25x1 20x25x1 20x25x1
1600CFMandover# .... 16x25x1(2) 16x25x1(2) 16x25x1(2) 16x25x1(2) 16x25x1(2)
Min. CoolCap.(Tons) 1.5 1.5 3 3 3 3 3
Max. CoolCap.(Tons) 3 3 4 5 5.5 5 5.5
Gas Conversion Kits
NattoLP NAHA001LP(1172958")
LPto Nat NAHA001NG(1172960")
* MustbeorderedfromServiceParts
441ol 261302 THIS DATA IS SUBJECT TO CHANGE WITHOUT NOTICE [_1