Sanyo SAP-KRV94EHDX Air Conditioner User Manual


 
Flap
Upper right screw
Grille
Screw cover
Screw
Lever
Lever
Front panel
UP
Sub-panel
Holding the part of the front panel adjacent to the arm.
Next, press the arm shaft against the upper part of the
groove which is located on the main body while
keeping the front panel almost horizontally, and push
it firmly until it makes a sound of being seated.
Front panel
(which is attached with a sub-panel on its rear side)
Arm
Groove
Arm shaft
Arm shaft
Arm
Groove
Close the front panel, and
push at the arrow to firmly fix it.
1.
2.
Loosen
Tighten
Tighten
Loosen
10-6. Checking and Troubleshooting when the Front Panel fails to work
10-6-1. Checking the Front Panel when it fails to work during operation
(1) Is the grille mounted in place?
(Check in particular that the upper right screw is
adequately tightened.)
(2) Are the five levers on the rear of the front panel
tightened?
The figure shows the loosened condition.
If the levers are in loosen, the front panel does
not work correctly.
(3) Is the front panel correctly mounted?
49