Outdoor Unit : SAP-CRV94EHDX, CRV124EHDX
8FA2-5257-57900-0
WHT
ORG
WHT
BLK
REACTANCE
L2L1
OUT
+
IN
+
IN
-
OUT
-
(WHT)
T-RUN/TEST
(
BLK
)
COIL/OUTDOOR
(
WHT
)
COMP/SUCTION
(
WHT
)
DCFM
(
BLK
)
MV
RV0RV1
DEF0
ACIN2
ACIN1
DEF1
25A
CONTROLLER
FM
CM
COMPRESSOR
MOTOR
BLK
BLK
BLU
YEL
YEL
YEL
RED
BLK
WHT
BLU
WHT
FERRITE
CORE
RT
S
GRN/YEL
GRN/YEL
FAN MOTOR
Meaning of Abbreviations
SUCTION
THERMISTOR
COMPRESSOR
THERMISTOR
OUT DOOR
THERMISTOR
COIL
THERMISTOR
RED
(
PNK
)
12
12
RV
RV
MV
BLU
BLU
BLU
BLU
2WAY VALVE
COIL
4WAY VALVE
COIL
MAGNETIC COIL
2P-CONNECTOR (
WHT
)
12
12
2P-CONNECTOR (
BLK
)
3
1
2
4
WHT
BLK
GRN/YEL
RED
TERMINAL
PLATE
E
SI
BLK
BLK
BLK
BLK
BLK
BLK
BLK
GRY
RED
ORG
YEL
WHT
GRY
GRY
1234
1234
1234
1234
567
56
1234
1234
56
56 7
1234
1234
1
2
3
U
V
W
GND
1
2
3
4
5
6
7
8
9
10
11
ABBREV.
BLK
BLU
BRN
GRN/YEL
GRY
ORG
PNK
RED
VLT
WHT
YEL
MEANING
BLACK
BLUE
BROWN
GREEN/YELLOW
GREY
ORANGE
PINK
RED
VIOLET
WHITE
YELLOW
Indoor Unit : SAP-KRV94EHDX, KRV124EHDX
1
4
2
3
JOINT BOX
POWER
RELAY
BLU
BRN
GRN/YEL
TERMINAL
BASE
GRN/YEL
EVAPORATOR
EARTH PLATE
3
1
2
BRN
BLU
GRN
RED
ORG
YEL
UV
(
RED
)
NET
(
BLU
)
LAMP1
(
WHT
)
ROOM
/COIL
(
WHT
)
HUM
(
RED
)
SW2
(
BLU
)
PANEL
(
WHT
)
ION
(
WHT
)
SW
(
WHT
)
DCM
(
BLU
)
FLAP1
(
WHT
)
JB1
(
WHT
)
JB2
(
WHT
)
CONTROLLER
HA
JEM-A
(
WHT
)
1 3 5 7
1 3 5 7
1 3 2 4
1 3 2 4
1
2
1
2
RED
BLK
UV UNIT
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
IND LAMP
ASSY
(
WHT
)
WHT
GRY
GRY
GRY
GRY
GRY
GRY
GRY
GRY
1
2
3
4
1
2
3
4
5
6
7
8
9
5
6
7
8
9
1
2
3
4
5
THERMISTOR
(ROOM)
THERMISTOR
(COIL)
THERMISTOR
(HUM)
PANEL SW
PANEL MOTOR
BLK
BLK
BLK
BLK
BLK
ORG
ORG
WHT
8FA2-5257-53400-1
STEP3
BRN
RED
ORG
YEL
PNK
BLU
1
2
3
4
1
2
3
4
5
6
5
6
1
2
3
4
1
2
1
2
1
2
1
2
1
2
3
4
1 2 3 4
1
2
3
4
1
2
3
4
WHT
RED
BLK
BLK
(
WHT
)
ION UNIT
BLK
ION
TERMINAL
(
WHT
)
SW ASSY
WHT
BLU
BLU
BLU
BLU
BLU
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
WHT
RED
BLU
BLK
YEL
FM
DC FAN MOTOR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
WHT
GRY
GRY
GRY
GRY
WHT
WHT
GRY
GRY
GRY
GRY
BLU
BLU
BLU
BLU
WHT
BLU
BLU
BLU
BLU
UPPER/LOWER
FLAP MOTOR
(UPPER)
UPPER/LOWER
FLAP MOTOR
(LOWER)
LEFT/RIGHT
FLAP MOTOR
(RIGHT)
LEFT/RIGHT
FLAP MOTOR
(LEFT)
(
WHT
) (
RED
)
(
WHT
) (
WHT
)
(
WHT
) (
WHT
)
(
WHT
) (
RED
)
FLAP4
(
BLU
)
FLAP3
(
WHT
)
FLAP2
(
BLU
)
FLAP1
(
PNK
)
1
2
3
4
1
2
3
4
5 5
1
2
3
4
1
2
3
4
5 5
1
2
3
4
1
2
3
4
5 5
1
2
3
4
1
2
3
4
5 5
1
2
3
4
1
2
3
4
5
6
5
6
3
2
1
3
2
1
POWER SUPPLY
EVAPORATOR
GRN
6-2. Electric Wiring Diagrams
Indoor Unit SAP-KRV94EHDX SAP-KRV124EHDX
Outdoor Unit SAP-CRV94EHDX SAP-CRV124EHDX
WARNING
To avoid electrical shock hazard, be sure to
disconnect power before checking, servicing
and/or cleaning any electrical parts.
21