Samsung SSA-P102T Home Security System User Manual


 
English _ 9
PRODUCT INTRODUCTION
CABLE SELECTION
Item
Cable Type
1
DC 12V Product Power
This
product
Belden #9409, 18 AWG 2 Conductor, Unshielded
2
Reader (Power and Data) External
Reader
This product
Belden #9512, 22 AWG 4 Conductor, Shielded
Belden #9514, 22 AWG 8 Conductor, Shielded
3
Door Contact Sensor
Exit Button
Sensor Input
Input
This product
Belden #9512, 22 AWG 4 Conductor, Shielded
Belden #9514, 22 AWG 8 Conductor, Shielded
4
Door Lock
Alarm Device
Lock (Alarm)
This product
Belden #9409, 18AWG 2 Conductor, Unshielded
5
RS-232 Cable
Converter
Host P.C.
Belden #9829, 24 AWG 2-twisted pair, Shielded
6
RS-485 Cable
SSA-P102
SSA-P102
SSA-P102
Converter
Belden #9829, 24 AWG 2-twisted pair, Shielded
RS-422 Cable
SSA-P102
SSA-P102
SSA-P102
Converter
Belden #9830, 24 AWG 3-twisted pair, Shielded
The cables should be thick enough to allow the maximum current consumed by the reader.
J
HOST PC
RS-232 RS-422/RS-232
Converter
RS-422
RF Reader
Exit Button/Sensor Input
Lock/Alarm
DC12V
Power Supply
RS-422 RS-422
RF Reader
Exit Button/Sensor Input
Lock/Alarm
DC12V
Power Supply