Samsung SSA-P102T Home Security System User Manual


 
20_ initialization
initialization
BOARD ID SETTING
Each device in the multi-serial communication connection is assigned with a
unique number to identify each other.
The initial value of the switch is “0”, and all of the 8 switches are
defaulted to OFF.
Each switch has a unique value, and the board ID is the sum of the
values of the switches.
You can specify a value between 0 and 31 for the board ID.
Refer to the example below for the board ID.
Example 1 Example 2 Example 3
Board ID: 0 (default) Board ID: 2+4 = 6 Board ID: 1+16 = 17
The board ID becomes the address of the device so the controllers in the same loop should be identifi ed with each
other.
COMMUNICATION SPEED SETUP
The initial value of the switch is “0”, and all of the 8 switches are
defaulted to OFF.
Each changing the switch makes a beep, and the communication
speed changes immediately upon the switch setting.
Use the switch to set the value.
9600 bps
(Default Setting)
4800 bps 19200 bps 38400 bps 57600 bps 115200 bps
You can select only one value from the 6 examples below for the communication speed.
However, the communication speed should match that of the host PC.
1.
2.
M
1.
2.
M
Device Address and
Communication Speed
Address
Communication Speed
Device Address and
Communication Speed