Samsung SSA-P102T Home Security System User Manual


 
English _ 17
INSTALLATION AND EXTERNAL CONNECTION
RS-422 Communication Port Connection (Multiple Units)
The RS-422/RS-232 converter is required to establish RS-422 communications with SSA-P102.
- Follow the guidelines below to make connection between devices.
Connect TX(-) of one device to TX(-) of other one.
Connect TX(+) of one device to TX(+) of other one.
Connect RX(-) of one device to RX(-) of other one.
Connect RX(+) of one device to RX(+) of other one.
Set a unique board ID for each product.
- Follow the guidelines below to make connection between the terminal device and the RS-422 9-pin
connector of the RS-422/RS-232 converter.
Connect RS-422-TX(-) to the RX(-) port of the converter.
Connect RS-422-TX(+) to the RX(+) port of the converter.
Connect RS-422-RX(-) to the TX(-) port of the converter.
Connect RS-422-RX(+) to the TX(+) port of the converter.
Connect the 9-pin connector of the RS-422/RS-232 converter to the COM port of the computer.
Install and launch the application (SAMS).
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
6.
T+ T- R+ R-
RxD
TxD
Power
RS-232C
RS-422/232
Converter
HOST
MAX. 1200m
TX-
TX+
RX-
RX+
SSA-P102