Rinnai E75CP Boiler User Manual


 
Installation & Servicing Instructions Rinnai E-Series
5
1.4 The following instructions must be followed
- The boiler must only be used for its designated purpose, as described in the
Installation Instructions.
- Each unit is tted with a data plate. Consult the details on this plate to verify whether
the boiler is compliant with its intended location, e.g.: gas type, power source and
venting classication.
-
Only use the boiler with the accessories and spare parts listed.
- Other combinations, accessories and consumables must only be used if they are
specically designed for the intended application and do not affect the system
performance and the safety requirements.
- Maintenance and repairs must only performed by trained professionals.
- Installation of a condensing gas boiler must be reported to the relevant gas utility
company and have it approved.
- You are only allowed to operate the condensing gas boiler with the vent system
that has been specically designed and approved for this type of boiler.
- Please note that local permission for the vent system and the condensate water
connection to the public sewer system may be required.
You must also respect:
- The local building codes stipulating the installation rules.
- The local building codes concerning the air intake and outlet systems and the
chimney connection.
- The regulations for the power supply connection.
- The technical rules laid down by the gas utility company concerning the connection
of the gas connection to the local gas mains.
- The instructions and standards concerning the safety equipment for the water/
space heating system.
- The Installation Instructions for building heating systems.
- The boiler must be located in an area where leakage of the boiler or connections
will not result in damage to the area adjacent to the boiler or to lower oors of
the structure. When such locations cannot be avoided, it is recommended that a
suitable drain pan be installed under the boiler.
- The boiler must be installed in such way that the all components are protected
from water (dripping, spraying, rain etc.) during boiler operation and service.
- The boiler must not be installed on or against carpeting.
- Do not restrict or seal any air intake or outlet openings.
- If you nd any defects, you must inform the owner of the system of the defect and
the associated hazard in writing.
DANGER. Gas is ammable and may cause an explosion.
Beware if you smell gas: there may be an explosion hazard!
If the information in these instructions is not followed exactly, a re or explosion may
result causing property damage, personal injury or death.
- Do not store or use gasoline or other ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- Do NOT try to light any appliance.
- Do NOT touch any electrical switch.
- Do NOT use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
- If you cannot reach your gas supllier, call the re department.
Should overheating occur or the gas supply fail to shut off, do not turn off
or disconnect the electrical supply to the pump. Instead, shut off the gas
supply at a location external to the appliance.
!
DANGER
!
WARNING