Regency GF55 Indoor Fireplace User Manual


 
Green re Pellet Stove and Insert Technical Manual
8
INSTALLATION
INSTALLATION
1. Check clearances to combustibles. See "Clearance to Combustibles"
section.
2. Do not obtain combustion air from an attic, garage or any unventilated
space if enough air is available. Combustion air may be obtained from
a ventilated crawlspace.
3. Do not install the stove in a bedroom.
4. You can vent the stove through an exterior wall behind the unit or
connect it to an existing masonry or metal chimney (must be lined if
the chimney is over 6” (15 cm) diameter, or over 28 inches² (180 cm²)
cross sectional area). An interior vent can be used with approved pipe
passing through the ceiling and roof.
REMOVING PELLET STOVE
FROM PALLET
To remove your new stove from its pallet, remove the two (2) screws
securing the bottom to the pallet.
Freestanding:
One screw can be easily seen from behind but to access the second screw
the ashpan must be removed. See gure 1.
Figure 1: Removing GF55 From Pallet.
Figure 2: Removing GFI55 From Pallet.
Fireplace Insert:
There is one screw on either side of the bottom. See gure 2.
LOCATING THE PELLET APPLIANCE
5. Locate the stove in a large and open room that is centrally located in
the house. This will optimize heat circulation.
6. The power cord is 8 feet (2.43 m) long and may require a grounded
extension cord to reach the nearest electrical outlet.
OPENING THE DOOR
The door lever can be found inbehind the right side of the door frame. To open the door, pivet the lever outwards and upwards until it unlocks.